SL 851 C - Exploration
Motor connection cable with overall copper screen 0.6/1 kV
Marking for SL 851 C - Exploration 08510425: SAB BRÖCKSKES · D-VIERSEN · SL 851 C - Exploration 4x2,5mm² x AWM Style 21223 80°C 1000V cxus AWM I/II A/B 80°C 1000V FT1 FT2 CE
Application
Motor connection cable for the electrical hook-up of drilling equipment, compressors, generators as well as pumps in rough environments.
For DNC motors on frequency converters U^ 1,7 kV.
Outstanding features
- UL/cUL recognized
- extremely large temperature range
- low surface transfer impedance
- low mutual capacitance
- very good EMC characteristics
Construction
Conductor | bare copper strands acc. to IEC 60228, VDE 0295, class 5 |
---|---|
Insulation | SABIX® |
Colour code | coloured acc. to HD 308 (VDE 0293-308) and a green-yellow earth wire |
Screen | alu foil and tinned copper braiding |
Wrapping | non-woven tape |
PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 | PUR, TMPU nach EN 50363-10-2 + VDE 0207-363-10-2 |
Sheath colour | black (RAL 9005) |
bare copper strands acc. to IEC 60228, VDE 0295, class 5
SABIX®
coloured acc. to HD 308 (VDE 0293-308)
and a green-yellow earth wire
alu foil and tinned copper braiding
non-woven tape
PUR, TMPU nach EN 50363-10-2 + VDE 0207-363-10-2
black (RAL 9005)
Technical data
Nominal voltage | Uo/U 0,6/1 kV |
---|---|
Voltage UL/cUL | 1000 V |
Maximum operating voltage | in three-phase current and single phase current operation: Uo/U 0,7/1,2 kV in D.C. current operation: Uo/U 0,9/1,8 kV peak value of alterning current: U^ 1,7 kV |
Testing voltage | core/core 4000 V core/screen 4000 V |
Min. bending radius | ≤ 12 mm > 12 mm bis ≤ 20 mm > 20 mm fixed laying: 5 x d 7,5 x d 10 x d flexible application: 10 x d 15 x d 20 x d |
Temperaturbereich | DIN VDE fixed laying: -50/+90 °C DIN VDE flexible application*: -45/+90 °C UL/cUL: up to +80 °C
*protected installation |
Cold resistance | -50°C acc. to DIN EN 60811-506 |
Halogen-free: | acc. to IEC 60754-1 + VDE 0482-754-1 |
Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, cUL FT1 FT2 |
Oil resistance | very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
MUD resistance | very good - acc. to IEC 60092-360, IEC 61892-4, NEK TS 606 |
Sunlight resistance | acc. to HD 605 |
Ozone resistance | acc. to DIN EN 50396 |
Salt water resistance | acc. to UL 1309 |
Absence of harmful substances | gemäß RoHS-Richtlinie der Europäischen Union |
Uo/U 0,6/1 kV
1000 V
in three-phase current and single phase current operation: Uo/U 0,7/1,2 kV
in D.C. current operation: Uo/U 0,9/1,8 kV
peak value of alterning current: U^ 1,7 kV
core/core 4000 V
core/screen 4000 V
≤ 12 mm > 12 mm bis ≤ 20 mm > 20 mm
fixed laying: 5 x d 7,5 x d 10 x d
flexible application: 10 x d 15 x d 20 x d
DIN VDE fixed laying: -50/+90 °C
DIN VDE flexible application*: -45/+90 °C
UL/cUL: up to +80 °C
*protected installation
-50°C acc. to DIN EN 60811-506
acc. to IEC 60754-1 + VDE 0482-754-1
flame retardant and self-extinguishing acc. to
IEC 60332-1-2 + VDE 0482-332-1-2, cUL FT1 FT2
very good - TMPU
acc. to EN 50363-10-2 + VDE 0207-363-10-2
very good - acc. to IEC 60092-360, IEC 61892-4, NEK TS 606
acc. to HD 605
acc. to DIN EN 50396
acc. to UL 1309
gemäß RoHS-Richtlinie der Europäischen Union
Dimensions
item no. |
No. of cores x cross section | AWG |
Largest single wire-ø | Outer-ø ± 10% | Copper figure | Cable weight ≈ | |
---|---|---|---|---|---|---|---|
08510425 | 4 x 2,50 mm² | 14 / 4c | 0,26 mm | 10 mm | 124,5 kg/km | 168 kg/km | Send inquiry |
08510440 | 4 x 4,00 mm² | 12 / 4c | 0,31 mm | 12,3 mm | 206,6 kg/km | 265 kg/km | Send inquiry |
08510460 | 4 x 6,00 mm² | 10 / 4c | 0,31 mm | 14 mm | 315,9 kg/km | 386 kg/km | Send inquiry |
08510470 | 4 x 10,00 mm² | 8 / 4c | 0,41 mm | 17 mm | 494,6 kg/km | 633 kg/km | Send inquiry |
08510480 | 4 x 16,00 mm² | 6 / 4c | 0,41 mm | 22,1 mm | 753,6 kg/km | 931 kg/km | Send inquiry |
08510490 | 4 x 25,00 mm² | 4 / 4c | 0,41 mm | 25,9 mm | 410,3 kg/km | 705 kg/km | Send inquiry |
08510495 | 4 x 35,00 mm² | 2 / 4c | 0,41 mm | 29,8 mm | 1522,8 kg/km | 1810 kg/km | Send inquiry |
08510496 | 4 x 50,00 mm² | 1 / 4c | 0,41 mm | 33,3 mm | 2110,1 kg/km | 2486 kg/km | Send inquiry |
08510498 | 4 x 70,00 mm² | 2/0 / 4c | 0,41 mm | 39,7 mm | 2897,9 kg/km | 3452 kg/km | Send inquiry |
cross section
wire-ø
Other dimensions and colours are possible on request.