Special Cables • Temperature Measurement • Cable Harnessing

6Ybl · 6Yvz

FEP insulated hook-up wire with extended temperature range, 375 V

Application

6Ybl · 6Yvz is an FEP insulated hook-up wire with extended temperature range and low and high temperature resistance 375 V. It is recommended for use in high-frequency and broad-band techniques, coaxial and microwave techniques, high information velocity with exact information transmission at the same time, chemical industry, furnace construction, brick works, and heating applicances.

Outstanding features

  • excellent resistance against chemicals and solvents
  • excellent temperature resistance and flexibility at low temperatures
  • excellent electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics

Additional information

     FEP (6Y)

     bare copper

      item no.

      FEP (6Y)

      tinned copper

           item no.
      AWG

      nominal Ø

      single wire

           Ø mm

      max.

      outer-Ø

          mm

      copper

       figure

        kg/km

      cable

      weight

       ≈ kg/km
      3303 .. 28        3304 .. 28        28         0,321        0,67        0,8          1,3
      3303 .. 26        3304 .. 26        26         0,405        0,76        1,2          1,9
      3303 .. 24        3304 .. 24        24         0,511        0,86        2,0          2,7
      3303 .. 22        3304 .. 22        22         0,644        0,99        3,2          4,0
      3303 .. 20        3304 .. 20        20         0,812        1,16        5,0          5,9

 

                                                                              Other dimensions and colours are possible on request.

 

ETFE, FEP, PFA colour code,

figures 5 and 6 item-no.:

 

01 = black05 = yellow09 = orange
02 = blue06 = green11 = red
03 = brown07 = violet15 = nature
04 = grey08 = white 

 

Cable construction

Conductor

bare or tinned copper wire

acc. to ASTM B 286

Insulation

FEP, 6YI1 acc. to VDE 0207-6

Technical data

Peak operating voltage

max. 375 V

Testing voltage

1500 V

Installation

for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated wire

Radiation resistance

1 x 10^7 cJ/kg

Temperature range

fixed laying: -90/+180°C

flexible application: -55/+180°C

limited time of use: +200°C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Chem. resistance

very good against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds – FEP has a slightly better resistance than ETFE

Absence of harmful substances

acc. to RoHS directive of the European Union