HV measuring cable for DC voltage measurement (cable harness)

Application

Safe HV measurement of DC voltages

Additional information

SAB identification: item number, batch number

Cable data

Connection cable

HV measuring cable

Core insulation

FEP – red and black

Stranding

together

with tinned copper drain wire, AWG 24

Screen

100% screen with alu foil and braiding

Inner sheath

PUR – blue acc. to RAL 5024

Outer sheath

PUR

Sheath colour

orange with black vertical stripes

Outer diameter

unscreened

2 x 0,25 mm²: 5,2 mm

 

screened

2 x 0,25 mm²: 6,5 mm

4 x 0,25 mm²: 7,2 mm

2 x 0,50 mm²: 7,1 mm

2 x 1,00 mm²: 7,8 mm

2 x 1,50 mm²: 8,4 mm

Scoop-proof

1000 V DC over blue inner sheath

Operating voltage

1800 V DC

Temperature range

fixed laying: -50°C / +125°C

flexible application: -40°C / +125°C

short time use: +150°C (up to 3000 h)

Connection cable

HV measuring cable

Core insulation

FEP – red and black

Stranding

together

with tinned copper drain wire, AWG 24

Screen

100% screen with alu foil and braiding

Inner sheath

PUR – blue acc. to RAL 5024

Outer sheath

PUR

Sheath colour

orange with black vertical stripes

Outer diameter

unscreened

2 x 0,25 mm²: 5,2 mm

 

screened

2 x 0,25 mm²: 6,5 mm

4 x 0,25 mm²: 7,2 mm

2 x 0,50 mm²: 7,1 mm

2 x 1,00 mm²: 7,8 mm

2 x 1,50 mm²: 8,4 mm

Scoop-proof

1000 V DC over blue inner sheath

Operating voltage

1800 V DC

Temperature range

fixed laying: -50°C / +125°C

flexible application: -40°C / +125°C

short time use: +150°C (up to 3000 h)

Connection end

Stripping length

250 mm

Screen

led out with filler and insulated with shrinkable sleeve

Temperature range of single core

-55°C / +180°C

Stripping length

250 mm

Screen

led out with filler and insulated with shrinkable sleeve

Temperature range of single core

-55°C / +180°C

Connectors

Safety lab plugs

1000 V, CAT III, red and black, 4 mm cable lug M4

Safety lab plugs

1000 V, CAT III, red and black, 4 mm cable lug M4

Configuration example

item no. Connection cable length Length channel 1 Length channel 2 Connector
T645-062-9126500 mm250 mm250 mmsafety lab plugs + M4 cable lugs Send inquiry
item no.
Connection cable length
Length channel 1
Length channel 2
Connector
T645-062-912
6500 mm
250 mm
250 mm
safety lab plugs + M4 cable lugs

Total cable and channel lengths can be realised on customer’s request.

Measurement technology specifically for your application.

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00