HV connecting cable for acceleration sensors (IEPE)

Application

Safe HV acceleration measurement for example with CSM HV IEPE3 FL 100 measuring module

Outstanding features

  • contact protection - see presentation

Additional information

Issue of HV test certificate with reference to batch number due to optimum traceability.
Optional: Test and repair of already used sensors on request.

 

SAB identification: item number, batch number

Cable data

Connection cable

HV IEPE sensor cable

Core insulation

PFA – red, white, black, yellow

Bundle sheath

PFA – blue acc. to RAL 5015

Inner sheath

PUR – blue acc. to RAL 5024

Outer sheath

PUR

Sheath colour

orange with black vertical stripes

Stranding

optimised in layers

Outer diameter

approx. 4,3 mm

Dielectric strength

1000 V AC over second inner sheath

Temperature range

fixed laying: -50°C / +150°C

flexible application: -40°C / +150°C

Connection cable

HV IEPE sensor cable

Core insulation

PFA – red, white, black, yellow

Bundle sheath

PFA – blue acc. to RAL 5015

Inner sheath

PUR – blue acc. to RAL 5024

Outer sheath

PUR

Sheath colour

orange with black vertical stripes

Stranding

optimised in layers

Outer diameter

approx. 4,3 mm

Dielectric strength

1000 V AC over second inner sheath

Temperature range

fixed laying: -50°C / +150°C

flexible application: -40°C / +150°C

Sensor connection side

Connector

4-pin ¼-28 UNF socket for the connection of a triaxial IEPE acceleration sensor (also with 4-pin 8-36 UNF and 4-pin M4,5)

Screen

led out in bundle and insulated with shrinkable sleeve

Temperature range bundle channel

-55°C / +250°C

Connector

4-pin ¼-28 UNF socket for the connection of a triaxial IEPE acceleration sensor (also with 4-pin 8-36 UNF and 4-pin M4,5)

Screen

led out in bundle and insulated with shrinkable sleeve

Temperature range bundle channel

-55°C / +250°C

Connector

Lemo Redel male connector

with orange kink protection sleeve and black protecting cap, 8-pin, C-coded

1000 V AC voltage-stable – IP 67 when connected

Lemo Redel male connector

with orange kink protection sleeve and black protecting cap, 8-pin, C-coded

1000 V AC voltage-stable – IP 67 when connected

Tests

Cable test

core/core – 600 V AC - 1 min - acc. to IEC 60584-1 over second inner sheath in water bath –

5000 V AC – 5 min – with reference to EN 50264-2-1

Product test

Routine test of harnessed connector with reference to standard 61010-1 for measuring devices as well as VDE indications in our in-house ball bath (released by VDE).

Control of contact protection towards outside – 3000 V/1 min AC

Cable test

core/core – 600 V AC - 1 min - acc. to IEC 60584-1 over second inner sheath in water bath –

5000 V AC – 5 min – with reference to EN 50264-2-1

Product test

Routine test of harnessed connector with reference to standard 61010-1 for measuring devices as well as VDE indications in our in-house ball bath (released by VDE).

Control of contact protection towards outside – 3000 V/1 min AC

Configuration examples

item no. Connection cable length Length channel 1 Length grounding Connector
T642-062-6663000 mm100 mm200 mm4-Pin ¼ -28 UNF Send inquiry
T642-062-7946000 mm100 mm200 mm4-Pin ¼ -28 UNF Send inquiry
T642-062-6353000 mm100 mm200 mm4-Pin 8-36 UNF Send inquiry
item no.
Connection cable length
Length channel 1
Length grounding
Connector
T642-062-666
3000 mm
100 mm
200 mm
4-Pin ¼ -28 UNF
T642-062-794
6000 mm
100 mm
200 mm
4-Pin ¼ -28 UNF
T642-062-635
3000 mm
100 mm
200 mm
4-Pin 8-36 UNF

Total cable and channel lengths can be realised on customer’s request.

Measurement technology specifically for your application.

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00