HV connecting cable for acceleration sensors (IEPE)
Application
Safe HV acceleration measurement for example with CSM HV IEPE3 FL 100 measuring module
Outstanding features
- contact protection - see presentation
Additional information
Issue of HV test certificate with reference to batch number due to optimum traceability.
Optional: Test and repair of already used sensors on request.
SAB identification: item number, batch number
Cable data
Connection cable | HV IEPE sensor cable |
---|---|
Core insulation | PFA – red, white, black, yellow |
Bundle sheath | PFA – blue acc. to RAL 5015 |
Inner sheath | PUR – blue acc. to RAL 5024 |
Outer sheath | PUR |
Sheath colour | orange with black vertical stripes |
Stranding | optimised in layers |
Outer diameter | approx. 4,3 mm |
Dielectric strength | 1000 V AC over second inner sheath |
Temperature range | fixed laying: -50°C / +150°C flexible application: -40°C / +150°C |
HV IEPE sensor cable
PFA – red, white, black, yellow
PFA – blue acc. to RAL 5015
PUR – blue acc. to RAL 5024
PUR
orange with black vertical stripes
optimised in layers
approx. 4,3 mm
1000 V AC over second inner sheath
fixed laying: -50°C / +150°C
flexible application: -40°C / +150°C
Sensor connection side
Connector | 4-pin ¼-28 UNF socket for the connection of a triaxial IEPE acceleration sensor (also with 4-pin 8-36 UNF and 4-pin M4,5) |
---|---|
Screen | led out in bundle and insulated with shrinkable sleeve |
Temperature range bundle channel | -55°C / +250°C |
4-pin ¼-28 UNF socket for the connection of a triaxial IEPE acceleration sensor (also with 4-pin 8-36 UNF and 4-pin M4,5)
led out in bundle and insulated with shrinkable sleeve
-55°C / +250°C
Connector
Lemo Redel male connector | with orange kink protection sleeve and black protecting cap, 8-pin, C-coded 1000 V AC voltage-stable – IP 67 when connected |
---|
with orange kink protection sleeve and black protecting cap, 8-pin, C-coded
1000 V AC voltage-stable – IP 67 when connected
Tests
Cable test | core/core – 600 V AC - 1 min - acc. to IEC 60584-1 over second inner sheath in water bath – 5000 V AC – 5 min – with reference to EN 50264-2-1 |
---|---|
Product test | Routine test of harnessed connector with reference to standard 61010-1 for measuring devices as well as VDE indications in our in-house ball bath (released by VDE). Control of contact protection towards outside – 3000 V/1 min AC |
core/core – 600 V AC - 1 min - acc. to IEC 60584-1 over second inner sheath in water bath –
5000 V AC – 5 min – with reference to EN 50264-2-1
Routine test of harnessed connector with reference to standard 61010-1 for measuring devices as well as VDE indications in our in-house ball bath (released by VDE).
Control of contact protection towards outside – 3000 V/1 min AC
Configuration examples
item no. | Connection cable length | Length channel 1 | Length grounding | Connector | |
---|---|---|---|---|---|
T642-062-666 | 3000 mm | 100 mm | 200 mm | 4-Pin ¼ -28 UNF | Send inquiry |
T642-062-794 | 6000 mm | 100 mm | 200 mm | 4-Pin ¼ -28 UNF | Send inquiry |
T642-062-635 | 3000 mm | 100 mm | 200 mm | 4-Pin 8-36 UNF | Send inquiry |
Total cable and channel lengths can be realised on customer’s request.