SAB Kabel

SABIX® A 170 TWÖ

Flexible „Thinwall” single conductor - space and weight saving

Marking for SABIX® A 170 TWÖ 68700105: SAB BRÖCKSKES · D-VIERSEN · SABIX® A 170 TWÖ EN 50306-2 300V 1 x 0,5 mm² CE

Marking for SABIX® A 170 TWÖ 68700105: SAB BRÖCKSKES · D-VIERSEN · SABIX® A 170 TWÖ EN 50306-2 300V 1 x 0,5 mm² CE

Application

SABIX® A 170 TWÖ is a flexible "Thin-wall" single conductor that is also space and weight saving. Furthermore, it has an abrasion resistant surface and standardized safety. It is recommended for the use in the production of control cabinets, appliances and devices for communication technologies, household appliances, construction of generators and transformers, machine construction, and railway technologies.

Outstanding features

  • halogen-free
  • flame retardant
  • low smoke emission
  • smallest outer diameter
  • space-saving installation
  • light
  • abrasion resistant surface
  • standardized safety
  • accomplishes the fire protection levels 1 - 4 acc. to DIN 5510
  • EAC approval

    Additional information

    Especially for use in rail vehicles

    Construction

    Conductor

    tinned copper strands fine wires acc. to EN 50306-2 + VDE 0260-306-2

    Insulation

    Special SABIX®

    Colour code

    white (similar RAL 9010)

    Technical data

    Nominal voltage

    Uo 300 V

    Testing voltage

    4000 V

    Temperature range

    +105°C, with short circuit of 5 sec., +160°C

    Voltage test

    2000 V AC, 5 min.

    4800 V DC, 5 min.

    Dielectric strength

    4000 V AC

    D.c.-voltage strength

    300 V DC, 10 d/85°C

    current increase ≤ 10%

    Insulation resistance at 20°C

    0,5 mm² - 600 MΩ*km

    Insulation resistance at 90°C

    0,5 mm² - 0,3 MΩ*km

    Stripping of insulation

    easy

    Oil resistance IRM 902 at 100°C/24 h

    no tears, voltage test at 1,5 kV AC

    Fuel resistance IRM 903 at 70°C/168 h

    no tears, voltage test at 1,5 kV AC

    Resistance against acids N-oxalic acid solution at 23°C/168 h

    no tears, voltage test at 1,5 kV AC

    Alkaline resistance N-oxalic acid solution at 23°C/168 h

    no tears, voltage test at 1,5 kV AC

    Hot pressure resistance at 125°C/4 h

    impression depth ≤ 50%

    voltage test at 1,5 kV AC

    Dynamic penetration test

    0,5 mm² - Last 70 N

    Resistance to tear propagation

    at -15°C/3 h

    at +23°C/3 h

    at +85°C/3 h

    voltage test at 150 V AC

    Shrinking at 150°C

    <1,5 mm

    Blocking of conductors

    at 150°C/6 h

    no adhesion

    Cold bend test

    at -40°C

    Abrasion resistance

    0,5 mm² - load 7 N

    Ozone resistance

    method B, no tears

    voltage test at 1,5 kV AC

    Stress cracking resistance

    168 h at 180°C, no tears

    voltage test at 1,5 kV AC

    Flame propagation at core

    flame effect 60 s

    fire trace: <425 mm

    Flame propagation bundeled cores

    flame effect 20 min.

    fire trace: <1,5 m

    Acidity of corrosive gases

    pH min. 4,3

    conductivity max. 10,0 μS/mm

    Development of corrosive gases

    hydrogen chloride max. 0,5%

    fluorine max. 0,1%

    Smoke density

    category 4 ≥70%

    Dimensions

    item no.
    no. of cores
    nominal cross section
    min. outer-ø
    max. outer-ø
    cable weight ca.
    ohmic resistance at 20°C max.
    68700105
    1
    0,5 mm²
    1,15 mm
    1,45 mm
    5,5 kg/km
    40,1 Ω/km
    68700107
    1
    0,75 mm²
    1,35 mm
    1,65 mm
    8,2 kg/km
    26,7 Ω/km
    68700110
    1
    1 mm²
    1,45 mm
    1,8 mm
    10 kg/km
    20 Ω/km
    68700115
    1
    1,5 mm²
    1,95 mm
    2,3 mm
    14,6 kg/km
    13,7 Ω/km
    68700125
    1
    2,5 mm²
    2,5 mm
    2,85 mm
    23,7 kg/km
    8,21 Ω/km

    Highly flexible cables according to your special requirements

    Family business for construction and production since 1947

    Please send us your inquiry
    +49 (0)2162 898-0
    Monday to Thursday, 7.30–16.30
    Friday, 07.30–15.00