Technical Description of measuring insert for thermocouples

The following measuring insert for thermocouples are available as thermocouples:

  • thermocouple:
    1 x Typ K or 2 x Typ K
    1 x Typ J or 2 x Typ J
    1 x Typ L or 2 x Typ L
  • limit deviation: class 1 or 2 acc. to DIN EN 60584 for types K and J
  • ­limit deviation: with reference to DIN 43710 for type L
  • sheath: ø 1,5 mm; ø 3,0 mm; ø 4,5 mm; ø 6,0 mm or 6,0 mm with measuring tip ø 8,0 mm
  • transmitter: with 1 or 2 transmitters

The following gauge slides are available as resistance thermometers:

  • resistance thermometer: 1 x Pt 100 or 2 x Pt 100 in 2-, 3-, 4-wire circuit
  • temperature range: -50°C/+400°C or -50°C/+600°C
  • limit deviation: class A or B acc. to DIN EN 60751
  • ­sheath: ø 1,6 mm; ø 3,0 mm; ø 4,5 mm; ø 6,0 mm or 6,0 mm with measuring tip ø 8,0 mm
  • transmitter: with one or two transmitters

Every gauge slide manufactured at SAB has a type plate at its lower side indicating for example:

  • SAB item no: T 752-041-724
  • type/number of thermocouples: 2 x type K
  • temperature range: -40°C / +1100°C
  • SAB work order no.: T084815
  • week and year of production: 37/07
  • accuracy

Do you have any questions about our products? Your direct line to our experts! Contact

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30