Selection table for railway cables
The selection table for railway cables is a first step towards the right cable choice for your special application. You will find the technical data and characteristics of cables on the corresponding catalogue pages. In case that you don´t find the suitable cable we are always prepared to assist you to choose the appropriate type. On demand of our customers we design and produce special cables that correspond exactly to their demands and application range.
You would like to have a direct contact to our experts? Please call us or send an e-mail!
Cable type | SABIX A 146 FRNC | SABIX A 156 FRNC | CATLine CAT 5e R CATLine CAT 6A R CATLine CAT 7A R | CATLine CAT 5e R flex CATLine CAT 6A R flex CATLine CAT 7A R flex | R 107 | SABIX® USB 2.0 R flex | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Applications | Single conductor | ⬤ | ⬤ |
|
|
|
|
|
|
|
|
| ⬤ | |||||||
Multi-core cable | ⬤ | ⬤ | ⬤ | |||||||||||||||||
screened |
|
| ⬤ | ⬤ |
|
| ⬤ | |||||||||||||
Wiring cable | ⬤ | ⬤ |
|
|
|
|
|
|
|
|
| |||||||||
Data cable |
|
|
|
|
|
|
| |||||||||||||
Control cable |
|
|
| |||||||||||||||||
| Ethernet cable | ⬤ | ⬤ | ||||||||||||||||||
| USB 2.0 cable | ⬤ | |||||||||||||||||||
cross linked type |
|
|
|
|
|
| ||||||||||||||
Standards |
| tested acc. to EN 45545-2 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||||||||||
Halogen-free | acc. to EN 50306-1 + EN 50264-1 are fulfilled. | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | |||||||||||||
Fire performance | No flame propagation | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | |||||||||||||
| Flame retardant acc. to UL 1685 section 12, FT4/IEEE 1202 (NFPA 130) | ⬤ | ⬤ | ⬤ | |||||||||||||||||
Burning test acc. to ASTM E 162-09 |
|
|
|
|
|
|
|
| ||||||||||||
Flame retardant acc. to ISO 6722 (UN/ECE R118) | ⬤ | ⬤ | ⬤ | ⬤ |
|
|
| |||||||||||||
| Insulation integrity in case of fire |
|
|
|
|
|
|
|
|
| ||||||||||
Toxicity acc. to EN 50305 + VDE 0260-305 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||||||||||||
Smoke density acc. to IEC 61034 + VDE 0482-1034 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||||||||||||
Smoke density acc. to ASTM E 662-09 |
|
|
|
|
|
|
|
| ||||||||||||
| Oil and fuel resistance acc. to EN 50264-1 + VDE 0260-264-1 | ⬤ | ⬤ | ⬤ | ⬤ | ||||||||||||||||
good ozone, UV and weather resistance |
|
|
|
|
|
|
|
| ⬤ | |||||||||||
Temperature | + 250 °C | |||||||||||||||||||
| + 180 °C | ||||||||||||||||||||
+ 125 °C |
|
|
|
|
|
| ||||||||||||||
+ 90 °C | ||||||||||||||||||||
| + 70 °C | ||||||||||||||||||||
– 40 °C | ||||||||||||||||||||
– 50 °C | ||||||||||||||||||||
Voltage | Peak operating voltage max. 30 V | ⬤ | ||||||||||||||||||
| Peak operating voltage max. 90 V | ⬤ | ⬤ | ||||||||||||||||||
Peak operating voltage: |
|
|
|
|
|
|
| |||||||||||||
Nominal voltage Uo/U 300/500 V | ⬤ |
|
|
| ||||||||||||||||
| Nominal voltage Uo/U 450/750 V | ⬤ | |||||||||||||||||||
Nominal voltage Uo/U 0,6/1 kV |
|
|
|
|
|
|
|
|
| |||||||||||
| Nominal voltage Uo/U 1,8/3 kV | ⬤ | |||||||||||||||||||
| Testing voltage 600 V | ⬤ | |||||||||||||||||||
Testing voltage 1500 V |
|
|
|
| ⬤ | ⬤ |
|
|
| |||||||||||
Testing voltage 2000 V | ⬤ |
|
|
|
|
| ||||||||||||||
| Testing voltage 2500 V | ⬤ | |||||||||||||||||||
Testing voltage 3000 V |
|
|
|
|
|
|
|
| ||||||||||||
Testing voltage 4000 V |
|
|
|
|
|
|
|
|
| |||||||||||
| Testing voltage 6500 V | ⬤ | |||||||||||||||||||