SAB Kabel

SABIX® A 285 FRNC X

Control cable with numbered cores and overall copper screen, cross-linked type tested acc. to EN 45545-2

Marking for SABIX® A 285 FRNC X 62850505: SAB BRÖCKSKES • D-VIERSEN • SABIX® A 285 FRNC X 5 x 0,5 mm² CE

Marking for SABIX® A 285 FRNC X 62850505: SAB BRÖCKSKES • D-VIERSEN • SABIX® A 285 FRNC X 5 x 0,5 mm² CE

Application

SABIX® A 285 FRNC X is a control cable with numbered cores and overall copper screen. Furthermore, it has a good ozone, oil, and chemical resistance. The flame retardant cable is recommended for the internal wiring of rail vehicles acc. to EN 45545-2.

Outstanding features

    • halogen-free
    • screened, good EMC characteristics
    • no flame propagation
    • flame retardant and self-extinguishing
    • good ozone resistance
    • good oil and chemical resistance
    • fulfils fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3
    • EAC approval

    Additional information

    Especially for use in rail vehicles

    Construction

    Conductor

    tinned copper strands fine wires acc. to IEC 60228, VDE 0295, class 5

    Insulation

    Special SABIX®

    Colour code

    white cores with consecutive numbers acc. to. EN 50334 + VDE 0293-334

    Stranding

    in layers

    Wrapping

    foil

    Screen

    tinned copper braiding

    Sheath material

    Special SABIX®

    Sheath colour

    black (RAL 9005)

    Technical data

    Nominal voltage

    Uo/U 300/500 V

    Testing voltage

    core/core 2000 V

    core/screen 2000 V

    Min. bending radius

    10 x d

    Temperature range

    during protected, fixed laying: -50/+125 °C

    Halogen-free

    acc. to EN 50306-1 + EN 50264-1 are fulfilled.

    Development of HCl is < 0,5% acc. to IEC 60754-1.

    pH-value is > 4,3 acc. to IEC 60754-2.

    Conductivity is < 10,0 µS/mm acc. to IEC 60754-2.

    Fluoric content < 0,1% acc. to IEC 60684-2

    Fire performance

    No flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24 resp. IEC 60332-3-25 + VDE 0482-332-3-25 and EN 50305 + VDE 0260-305 section 9.1.2.

    Flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

    Toxicity

    acc. to EN 50305 + VDE 0260-305

    Smoke density

    acc. to IEC 61034 + VDE 0482-1034

    Dimensions

    item no.
    no. of cores x cross section
    largest single wire-ø
    outer-ø ± 5%
    copper figure
    cable weight ca.
    ohmic resistance at 20°C max.
    heating value approx.
    62850305
    3 x 0,50 mm²
    0,21 mm
    5,2 mm
    30,3 kg/km
    45 kg/km
    40,1 Ω/km
    99 kWh/km
    62850505
    5 x 0,50 mm²
    0,21 mm
    6,3 mm
    43,5 kg/km
    68 kg/km
    40,1 Ω/km
    154 kWh/km
    62850805
    8 x 0,50 mm²
    0,21 mm
    7,9 mm
    62,2 kg/km
    97 kg/km
    40,1 Ω/km
    237 kWh/km
    62851005
    10 x 0,50 mm²
    0,21 mm
    8,6 mm
    74,3 kg/km
    114 kg/km
    40,1 Ω/km
    258 kWh/km
    62851205
    12 x 0,50 mm²
    0,21 mm
    8,9 mm
    86,6 kg/km
    127 kg/km
    40,1 Ω/km
    288 kWh/km
    62850607
    6 x 0,75 mm²
    0,21 mm
    7,7 mm
    67 kg/km
    101 kg/km
    26,7 Ω/km
    231 kWh/km
    62850807
    8 x 0,75 mm²
    0,21 mm
    9,1 mm
    86,6 kg/km
    132 kg/km
    26,7 Ω/km
    305 kWh/km
    62851007
    10 x 0,75 mm²
    0,21 mm
    10,4 mm
    119,7 kg/km
    172 kg/km
    26,7 Ω/km
    381 kWh/km
    62850310
    3 x 1,00 mm²
    0,21 mm
    6,2 mm
    46,5 kg/km
    66 kg/km
    20 Ω/km
    155 kWh/km
    62850610
    6 x 1,00 mm²
    0,21 mm
    8,2 mm
    83,7 kg/km
    125 kg/km
    20 Ω/km
    285 kWh/km
    62850810
    8 x 1,00 mm²
    0,21 mm
    9,8 mm
    106 kg/km
    160 kg/km
    20 Ω/km
    366 kWh/km
    62851010
    10 x 1,00 mm²
    0,21 mm
    10,8 mm
    149,9 kg/km
    200 kg/km
    20 Ω/km
    401 kWh/km

    Highly flexible cables according to your special requirements

    Family business for construction and production since 1947

    Please send us your inquiry
    +49 (0)2162 898-0
    Monday to Thursday, 7.30–16.30
    Friday, 07.30–15.00