Application
GP 400 Sy - PVC: The high-quality 400 Hz cable for fixed electrical ground power installations at airports
As a symmetrically designed 400 Hz power supply solution, the GP 400 Sy - PVC cable was developed specifically for fixed electrical ground power (FEGP) applications, such as between a 400 Hz generator and a cable dispenser at the gate. The PVC outer sheath and SABIX® insulation guarantee a long service life and operational reliability even under extreme conditions:
This cable features:
- Low capacitance, ideal for high frequencies with minimal contact resistance
- Temperature resistance from approx. -30°C to +70°C when installed in a fixed position
- Test voltage of up to 4000 V AC between conductors
- Compliance with CE and RoHS standards, supplemented by site safety thanks to halogen-free materials
In the long term, the GP 400 Sy PVC cable not only reduces maintenance and replacement costs, it also makes a significant contribution to reducing emissions, as APUs or mobile GPUs on the ground are no longer required. Thanks to its robust design, it is the ideal choice for permanently installed power supply systems in airport operations and provides long-term support for modern FEGP infrastructures.
Construction
| Conductor | bare copper strands, fine wires |
|---|---|
| Insulation | L34000402 1,0 mm²: SABIX® 35,0 mm²: PVC
L34000455 SABIX® |
| Colour code | 1,0 mm²: black with numbers 1 – 24 35,0 resp. 70,0 mm²: blue, 2 x white, 2 x brown, 2 x black |
| Stranding | 1,0 mm²: cores twisted as quads, wrapped with tape |
| Stranding | all elements optimized stranded in layers, wrapped with overlapping non-woven tape |
| Outer Sheath | PVC, orange |
bare copper strands, fine wires
L34000402
1,0 mm²: SABIX®
35,0 mm²: PVC
L34000455
SABIX®
1,0 mm²: black with numbers 1 – 24
35,0 resp. 70,0 mm²: blue, 2 x white, 2 x brown, 2 x black
1,0 mm²: cores twisted as quads, wrapped with tape
all elements optimized stranded in layers, wrapped with overlapping non-woven tape
PVC, orange
Technical Data
| Nominal voltage | Uo/U 115/200 V |
|---|---|
| Max. permissible operating voltage | Uo/U 0,6/1 kV |
| Testing voltage | core/core 4000 V AC 50 Hz |
| Min. bending radius | fixed laying: 4 x d flexible application: 6 x d for one single bend: 3 x d |
| Temperature range | fixed laying: -40°C/+70 °C flexible application: -30°C/+70 °C |
| Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
| Chemical resistance | good against acids, alkalines, solvents, hydraulic liquids, etc |
| Hydrolysis and microbial resistance | very good - acc. to EN 50363-10-2 |
| Salt water resistance | very good - acc. to UL 1309 |
| Oil resistance | very good - acc. to EN 50363-10-2 |
| Weather resistance | good |
| Ozone resistance | good |
| Absence of harmful substances | acc. to RoHS-Directive 2011/65/EU and Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU |
Uo/U 115/200 V
Uo/U 0,6/1 kV
core/core 4000 V AC 50 Hz
fixed laying: 4 x d
flexible application: 6 x d
for one single bend: 3 x d
fixed laying: -40°C/+70 °C
flexible application: -30°C/+70 °C
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
good against acids, alkalines, solvents, hydraulic liquids, etc
very good - acc. to EN 50363-10-2
very good - acc. to UL 1309
very good - acc. to EN 50363-10-2
good
good
acc. to RoHS-Directive 2011/65/EU and Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU
Dimensions
| item no. |
No. of cores x cross section | Outer-ø | Copper figure | Cable weight ≈ |
Ohmic resistance at 20°C max. | |
|---|---|---|---|---|---|---|
| L34000402 | 7 x 35,0 mm² + 6 x 4 x 1,0 mm² | min. 35,5 mm - max. 39,5 mm | 2582 kg/km | 3164 kg/km | 35,0 mm²: 0,554 Ω/km | 1,0 mm²: 19,5 Ω/km | Send inquiry |
| L34000455 | 7 x 70,0 mm² + 6 x 4 x 1,0 mm² | min. 48,0 mm - max. 52,0 mm | 4934 kg/km | 5780 kg/km | 70,0 mm²: 0,272 Ω/km | 1,0 mm²: 19,5 Ω/km | Send inquiry |
cross section
at 20°C max.
Other dimensions and colours are possible on request.