GP 400 QF- PUR

Supply cable - QuadFlex - PUR

Marking Example: SAB BRÖCKSKES · D-Viersen · GP 400 QF 4x(70,0mm²+4x1,0mm²) 3400-0050 ** CE and continuous meter marking / **Cable marking: L1, L2, L3 and N

Marking Example: SAB BRÖCKSKES · D-Viersen · GP 400 QF 4x(70,0mm²+4x1,0mm²) 3400-0050 ** CE and continuous meter marking / **Cable marking: L1, L2, L3 and N

Application

For use in flexible applications, e.g. on mobile GPUs, PIT systems and as a connecting cable between sleeve and plug in reeling applications.

Outstanding features

  • low capacity insulation
  • abrasion-resistant PUR sheath
  • cold flexible
  • halogen-free
  • oil resistant
  • weather resistant
  • with wear indicator

Construction

Conductor

tinned copper strands, fine wires acc. to IEC 60228 class 5

Insulation

SABIX®

Colour code

control cores: red, black, green, yellow

power supply core: red

Stranding

control cores within the power supply core

Inner sheath

PUR, red

Outer sheath

PUR, yellow

Stranding

open stranded

Conductor

tinned copper strands, fine wires acc. to IEC 60228 class 5

Insulation

SABIX®

Colour code

control cores: red, black, green, yellow

power supply core: red

Stranding

control cores within the power supply core

Inner sheath

PUR, red

Outer sheath

PUR, yellow

Stranding

open stranded

Technical data

Nominal voltage

Uo/U 115/200 V

Max. permissible operating voltage

Uo/U 0,6/1 kV

Testing voltage

core/core 4000 V AC 50Hz

Min. bending radius

fixed laying: 4 x d

flexible application : 6 x d

Temperature range

fixed laying: -50/+90 °C

flexible application: -40/+90 °C

limited time of use: +110 °C (7500 h)

Halogen-free

acc. to IEC 60754-1

Fire performance

sheath material: UL 94 V2

Oil resistance

very good - acc. to EN 50363-10-2-2

Chemical resistance

good against acids, alkalines, solvents, hydraulic liquids, etc.

Weather resistance

very good

Salt water resistance

very good - acc. to UL 1309

Hydrolysis and microbial resistance

very good - acc. to EN 50360-10-2

MUD resistance

very good - acc. to IEC 60092-360

Ozone resistance

very good- acc. to EN 50396

Ozone resistance

very good - acc. to EN 50396

Abrasion

acc. to UL 2556-2021 and JIS C3005

Fuel resistant

petrol, diesel and kerosene (Jet A-1)

Mechanical resistance

characteristics of the outer sheath:

- high tensile strength

- high tear strength

- high abrasion resistance

- high notch resistance

- high shear strength

Absence of harmful substances

acc. to RoHS directive of the European Union

Nominal voltage

Uo/U 115/200 V

Max. permissible operating voltage

Uo/U 0,6/1 kV

Testing voltage

core/core 4000 V AC 50Hz

Min. bending radius

fixed laying: 4 x d

flexible application : 6 x d

Temperature range

fixed laying: -50/+90 °C

flexible application: -40/+90 °C

limited time of use: +110 °C (7500 h)

Halogen-free

acc. to IEC 60754-1

Fire performance

sheath material: UL 94 V2

Oil resistance

very good - acc. to EN 50363-10-2-2

Chemical resistance

good against acids, alkalines, solvents, hydraulic liquids, etc.

Weather resistance

very good

Salt water resistance

very good - acc. to UL 1309

Hydrolysis and microbial resistance

very good - acc. to EN 50360-10-2

MUD resistance

very good - acc. to IEC 60092-360

Ozone resistance

very good- acc. to EN 50396

Ozone resistance

very good - acc. to EN 50396

Abrasion

acc. to UL 2556-2021 and JIS C3005

Fuel resistant

petrol, diesel and kerosene (Jet A-1)

Mechanical resistance

characteristics of the outer sheath:

- high tensile strength

- high tear strength

- high abrasion resistance

- high notch resistance

- high shear strength

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. No. of cores x
cross section
Outer-ø Copper figure Cable weight ≈ Ohmic resistance
max. Ω/km
L340000504 x (50,0 mm² + 4 x 1,0 mm²)approx. 38,6 (core max. 17,9)2096,0 kg/km2436 kg/km50,0 mm²: 0,393 Ω/km | 1,0 mm²: 20,0 Ω/km Send inquiry
L340000514 x (70,0 mm² + 4 x 1,0 mm²)max. 39,9 (core min. 16 - max. 16,6)2957,0 kg/km3174 kg/km70,0 mm²: 0,277 Ω/km | 1,0 mm²: 20,0 Ω/km Send inquiry
L340000574 x (70,0 mm² + 6 x 1,0 mm²)approx. 42,5 (core max. 17,9)2918,0 kg/km3241 kg/km70,0 mm²: 0,277 Ω/km | 1,0 mm²: 20,0 Ω/km Send inquiry
L340000614 x (35,0 mm² + 4 x 1,0 mm²)approx. 42,5 (core max. 17,9)1574,4 kg/km1913 kg/km35,0 mm²: 0,565 Ω/km | 1,0 mm²: 20,0 Ω/km Send inquiry
L340000644 x (95,0 mm² + 4 x 1,0 mm²)approx. 47,3 (core max. 21,0)3808,8 kg/km4294 kg/km70,0 mm²: 0,277 Ω/km | 1,0 mm²: 20,0 Ω/km Send inquiry
item no.
No. of cores x
cross section
Outer-ø
Copper figure
Cable weight ≈
Ohmic resistance
max. Ω/km
L34000050
4 x (50,0 mm² + 4 x 1,0 mm²)
approx. 38,6 (core max. 17,9)
2096,0 kg/km
2436 kg/km
50,0 mm²: 0,393 Ω/km | 1,0 mm²: 20,0 Ω/km
L34000051
4 x (70,0 mm² + 4 x 1,0 mm²)
max. 39,9 (core min. 16 - max. 16,6)
2957,0 kg/km
3174 kg/km
70,0 mm²: 0,277 Ω/km | 1,0 mm²: 20,0 Ω/km
L34000057
4 x (70,0 mm² + 6 x 1,0 mm²)
approx. 42,5 (core max. 17,9)
2918,0 kg/km
3241 kg/km
70,0 mm²: 0,277 Ω/km | 1,0 mm²: 20,0 Ω/km
L34000061
4 x (35,0 mm² + 4 x 1,0 mm²)
approx. 42,5 (core max. 17,9)
1574,4 kg/km
1913 kg/km
35,0 mm²: 0,565 Ω/km | 1,0 mm²: 20,0 Ω/km
L34000064
4 x (95,0 mm² + 4 x 1,0 mm²)
approx. 47,3 (core max. 21,0)
3808,8 kg/km
4294 kg/km
70,0 mm²: 0,277 Ω/km | 1,0 mm²: 20,0 Ω/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–13.30