Application
High-voltage cable for dynamic applications in drag chains. The HV Robot 1.8/3 kV was specially developed for use in high-voltage testing under dynamic conditions. In automated test environments where cables are constantly moving or guided through drag chains, high mechanical resilience is just as important as electrical safety.
With its robust SABIX®/PUR cable construction, the HV Robot offers an excellent combination of flexibility and abrasion resistance. UL/cUL approval (80 °C, 2000 V) confirms its suitability for international applications in test and automation technology.
Thanks to its long service life and voltage resistance, this cable is ideal for demanding drag chain applications, test benches, and high-voltage test systems in electromobility or industrial automation.
Outstanding features
- extremely flexible
- cULus recognized
- good EMC characteristics
- halogen-free
- flexible at low temperatures
- heat resistant
- flameretardend and self extinguishing
- weather resistant
- high protection against environmental influences
- extremely high mechanical resistance
- 100% oil resistance acc. to standard
- suitable for cable tracks and robots
- PWIS uncritical (PWIS = paint-wetting impairment substances)
- PFAS free
Construction
Conductor | bare copper strands acc. to IEC 60228, VDE 0295, class 6 |
---|---|
Insulation | SABIX® |
Wrapping | non-woven tape |
Screen | tinned copper braiding |
Wrapping | non-woven tape |
Sheath material | PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Sheath colour | orange (RAL 2003) |
bare copper strands
acc. to IEC 60228, VDE 0295, class 6
SABIX®
non-woven tape
tinned copper braiding
non-woven tape
PUR, TMPU
acc. to EN 50363-10-2 + VDE 0207-363-10-2
orange (RAL 2003)
Technical data
Nominal Voltage | Uo/U 1,8/3,0 kV AC Uo/U 2,7/5,4 kV DC |
---|---|
Voltage cULus | 2000 V |
Testing voltage | 6500 V |
Current-carrying capacity | acc. to VDE 0298-4 see chapter N "Technical data" |
Min. bending radius | fixed laying: 3 x d flexible application: 6 x d |
Temperature range | DIN VDE cULus up to +80°C fixed laying: -50/+90°C flexible application: -40/+90°C limited: +100°C / 10000h +125°C / 2000h |
Halogen-free | acc. to IEC60754-1 + VDE 0482-754-1 |
Brennverhalten | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, cULus FT1, FT2 |
Oil resistance | very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Chem. resistance | good against acids, alkalines, solvents, hydraulic liquids, etc. |
Hydrolysis and microbial resistance | very good acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Weather resistance | very good acc. to HD 605 |
Salt water resistance | very good acc. to UL 1309 |
Ozone resistance | very good acc. to DIN EN 50396 |
MUD resistance | very good acc. to IEC 60092-360, IEC 61892-4, NEK TS 606 |
Mechanical characteristics | the main mechanical characteristics accomplished by the PUR outer sheath are: - high tensile strength - high tear strength - high abrasion resistance - high notch resistance - high transverse strength |
Absence of harmful substances | acc. to RoHS directive of the European Union, see chapter N "Technical data" |
Uo/U 1,8/3,0 kV AC
Uo/U 2,7/5,4 kV DC
2000 V
6500 V
acc. to VDE 0298-4
see chapter N "Technical data"
fixed laying: 3 x d
flexible application: 6 x d
DIN VDE cULus up to +80°C
fixed laying: -50/+90°C
flexible application: -40/+90°C
limited: +100°C / 10000h
+125°C / 2000h
acc. to IEC60754-1 + VDE 0482-754-1
flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + VDE 0482-332-1-2,
cULus FT1, FT2
very good - TMPU
acc. to EN 50363-10-2 + VDE 0207-363-10-2
good against acids, alkalines, solvents,
hydraulic liquids, etc.
very good acc. to EN 50363-10-2 + VDE 0207-363-10-2
very good acc. to HD 605
very good acc. to UL 1309
very good acc. to DIN EN 50396
very good
acc. to IEC 60092-360, IEC 61892-4, NEK TS 606
the main mechanical characteristics
accomplished by the PUR outer sheath are:
- high tensile strength
- high tear strength
- high abrasion resistance
- high notch resistance
- high transverse strength
acc. to RoHS directive of the European Union, see chapter N "Technical data"
Dimensions
item no. |
Nominal cross section |
Largest single wire-ø | max. outer-ø | Copper figure | Cable weight ≈ |
Ohmic resistance at 20°C acc. to VDE 0812 max. Ω/km | |
---|---|---|---|---|---|---|---|
L39142507 | 25,0mm² | 0,21mm | 12,8mm | 300,7 kg/km | 346 kg/km | 0,78 | Send inquiry |
L39143507 | 35,0mm² | 0,21mm | 14,6mm | 403,4 kg/km | 466 kg/km | 0,554 | Send inquiry |
L39145007 | 50,0mm² | 0,31mm | 16,5mm | 580,0 kg/km | 654 kg/km | 0,386 | Send inquiry |
L39147007 | 70,0mm² | 0,31mm | 19,0mm | 786,9 kg/km | 876 kg/km | 0,272 | Send inquiry |
L39149507 | 95,0mm² | 0,31mm | 22,6mm | 1050,0 kg/km | 1179 kg/km | 0,206 | Send inquiry |
L39141207 | 120,0mm² | 0,31mm | 24,2mm | 1309,9 kg/km | 1438 kg/km | 0,161 | Send inquiry |
section
wire-ø
at 20°C acc. to VDE 0812
max. Ω/km