CATLine CAT 6A BL

CAT 6A halogen-free Ethernet cable with ABS Type Approval and UL recognition for maritime use

Marking example:
SAB BRÖCKSKES · D-VIERSEN · Cat.6A BL 4x2x26AWG 1747-4421 UL AWM Style 21080 75°C 300V CE

Marking example: SAB BRÖCKSKES · D-VIERSEN · Cat.6A BL 4x2x26AWG 1747-4421 UL AWM Style 21080 75°C 300V CE

Application

CAT 6A halogen-free Ethernet cable with ABS Type Approval and UL recognition for maritime use.

Outstanding features

  • ABS Type Approval
  • TR IEC 60092-370
  • UL recognition
  • halogen-free
  • asbestos-free
  • no flame propagation
  • flame retardant and self-extinguishing
  • good against aggressive chemicals
  • PFAS-free

Additional information

also possible as harnessed cable with M12 or RJ 45 plug

Not sure which bus cables are right for your application?

Compare more SAB bus cables and use their technical specifications to find the right cable for your application.

Compare and select bus cables

Construction

Dimension

4 x 2 x 24 AWG

4 x 2 x 26 AWG

Conductor

bare copper strands, fine wires

Insulation

special polymer

Colour code

white-blue/blue, white-orange/orange, white-green/green, white-brown/brown

Stranding

cores twisted to pairs, pairs together

Screen

alu foil and tinned copper braiding

Sheath material

special SABIX®

Sheath colour

black

Dimension

4 x 2 x 24 AWG

4 x 2 x 26 AWG

Conductor

bare copper strands, fine wires

Insulation

special polymer

Colour code

white-blue/blue, white-orange/orange, white-green/green, white-brown/brown

Stranding

cores twisted to pairs, pairs together

Screen

alu foil and tinned copper braiding

Sheath material

special SABIX®

Sheath colour

black

Technical data

Peak operating voltage

max. 90 V

Voltage UL

300 V

Testing voltage

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Temperature range VDE

fixes laying : - 40°C / + 70 °C

flexible application: - 30°C / + 70 °C

UL: up to + 75°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Flame propagation

no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A,

UL Horizontal Flame Test FT2, UL AWM Style 21080

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosiveness of conflagration gases

in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Smoke density

acc. to IEC 61034 + VDE 0482-1034

Characteristic impedance

100Ω ± 10Ω, fulfils the electrical and transmission requirements

with high frequency with reference to EN 50288-10-2 / CAT 6A

Flexibility

good

UL Style

21080

Application

suitable for EtherCAT and EtherNET/IP applications

Absence of harmful substances

acc. to RoHS directive of the European Union

Peak operating voltage

max. 90 V

Voltage UL

300 V

Testing voltage

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Temperature range VDE

fixes laying : - 40°C / + 70 °C

flexible application: - 30°C / + 70 °C

UL: up to + 75°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Flame propagation

no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A,

UL Horizontal Flame Test FT2, UL AWM Style 21080

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosiveness of conflagration gases

in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Smoke density

acc. to IEC 61034 + VDE 0482-1034

Characteristic impedance

100Ω ± 10Ω, fulfils the electrical and transmission requirements

with high frequency with reference to EN 50288-10-2 / CAT 6A

Flexibility

good

UL Style

21080

Application

suitable for EtherCAT and EtherNET/IP applications

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Dimension Outer-ø
± 10%
Copper figure Cable weight ≈
L164746214 x 2 x 26/7 AWG7,3 mm31,9 kg/km64 kg/km Send inquiry
L164744214 x 2 x 24/7 AWG8,3 mm41,1 kg/km81 kg/km Send inquiry
item no.
Dimension
Outer-ø
± 10%
Copper figure
Cable weight ≈
L16474621
4 x 2 x 26/7 AWG
7,3 mm
31,9 kg/km
64 kg/km
L16474421
4 x 2 x 24/7 AWG
8,3 mm
41,1 kg/km
81 kg/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–13.30

Hello!

Your preferred language does not match the language of this site. You can switch to the appropriate translation.