DR CB 689 P Highflex

reeling CAN-Bus cable

Marking example: SAB BRÖCKSKES · D-VIERSEN · DR CB 689 P Highflex 2 x 2 x 0,50 mm² CE

Marking example: SAB BRÖCKSKES · D-VIERSEN · DR CB 689 P Highflex 2 x 2 x 0,50 mm² CE

Application

Outstanding features

  • halogen-free
  • very good oil resistance
  • reeling cable
  • PFAS-free

Additional information

also possible as harnessed cable with M12 or RJ 45 plug

Not sure which bus cables are right for your application?

Compare more SAB bus cables and use their technical specifications to find the right cable for your application.

Compare and select bus cables

Construction

Dimension

2 x 2 x 0,50 mm²

Conductor

bare copper strands

Insulation

PE

Colour code

with reference to DIN 47100

Stranding

twisted to pairs and pairs together

Wrapping

non-woven tape

Screen

tinned copper braiding

Sheath material

PUR / supporting braid / PUR

Sheath colour

black (similar RAL 9005)

Dimension

2 x 2 x 0,50 mm²

Conductor

bare copper strands

Insulation

PE

Colour code

with reference to DIN 47100

Stranding

twisted to pairs and pairs together

Wrapping

non-woven tape

Screen

tinned copper braiding

Sheath material

PUR / supporting braid / PUR

Sheath colour

black (similar RAL 9005)

Technical data

Peak operating voltage

max. 350 V

Testing voltage

core/core 1500 V

core/screen 1200 V

Min. bending radius

for laying and installation (fixed laying): 5 x d

for repeated winding action (flexible): 7,5 x d

guided on pulleys (flexible): 10 x d

Temperature range

fixed laying: -40/+90°C

flexible application: -40/+90°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Oil resistance

TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2

Characteristic impedance

120Ω (95 - 140Ω)

Absence of harmful substances

acc. to RoHS directive of the European Union

Peak operating voltage

max. 350 V

Testing voltage

core/core 1500 V

core/screen 1200 V

Min. bending radius

for laying and installation (fixed laying): 5 x d

for repeated winding action (flexible): 7,5 x d

guided on pulleys (flexible): 10 x d

Temperature range

fixed laying: -40/+90°C

flexible application: -40/+90°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Oil resistance

TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2

Characteristic impedance

120Ω (95 - 140Ω)

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Dimension Outer-ø
± 10%
Copper figure Cable weight ≈ Ohmic resistance
at 20°C acc. to VDE 0812
max. Ω/km
Tensile strength
max.
L068990052 x 2 x 0,50 mm²12,8 mm48,8 mm175 kg/km39 Ω/km200 N Send inquiry
item no.
Dimension
Outer-ø
± 10%
Copper figure
Cable weight ≈
Ohmic resistance
at 20°C acc. to VDE 0812
max. Ω/km
Tensile strength
max.
L06899005
2 x 2 x 0,50 mm²
12,8 mm
48,8 mm
175 kg/km
39 Ω/km
200 N

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–13.30

Hello!

Your preferred language does not match the language of this site. You can switch to the appropriate translation.