Li6Ybl · Li6Yvz (900 V)

FEP insulated stranded hook-up wire with extended temp erature range, 900 V

Application

Li6Ybl · Li6Yvz is an FEP insulated stranded hook-up wire with extended temperature range and nearly frequency-independent dielectric characteristics 900 V. It is recommended for use in high-frequency and broad-band techniques, coaxial and microwave techniques, high information velocity with exact information transmission at the same time, chemical industry, furnace construction, brick works, and heating appliances.

Outstanding features

  • excellent resistance against chemicals and solvents
  • excellent temperature resistance and flexibility at low temperatures
  • excellent electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics

Additional information

ETFE, FEP, PFA colour code,

figures 5 and 6 item-no.:

 

01 = black05 = yellow09 = orange
02 = blue06 = green11 = red
03 = brown07 = violet15 = nature
04 = grey08 = white 

Construction

Conductor

bare or tined-plated copper strands

acc. to ASTM B 286

Insulation

FEP, 6YI1 acc. to VDE 0207-6

Conductor

bare or tined-plated copper strands

acc. to ASTM B 286

Insulation

FEP, 6YI1 acc. to VDE 0207-6

Technical data

Peak operating voltage

max. 900 V

Voltage UL

600 V

Testing voltage

2500 V

Installation

for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated wire

Radiation resistance

1 x 10⁷ cJ/kg

Temperature range

fixed laying: -90/+180°C

flexible application: -55/+180°C

limited time of use: 200 °C

UL: up to 150°C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 UL FT2

Oil resistance

very good, acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds – FEP has a slightly better resistance than ETFE

Absence of harmful substances

acc. to RoHS directive of the European Union

Peak operating voltage

max. 900 V

Voltage UL

600 V

Testing voltage

2500 V

Installation

for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated wire

Radiation resistance

1 x 10⁷ cJ/kg

Temperature range

fixed laying: -90/+180°C

flexible application: -55/+180°C

limited time of use: 200 °C

UL: up to 150°C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 UL FT2

Oil resistance

very good, acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds – FEP has a slightly better resistance than ETFE

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. AWG max. outer-ø Copper figure Cable weight ≈
3348 .. 28*28/7 AWG0,93 mm0,9 kg/km2 kg/km Send inquiry
3349 .. 28*28/7 AWG0,93 mm0,9 kg/km2 kg/km Send inquiry
3348 .. 26*26/7 AWG1,03 mm1,3 kg/km2,7 kg/km Send inquiry
3349 .. 26*26/7 AWG1,03 mm1,3 kg/km2,7 kg/km Send inquiry
3348 .. 24*24/7 AWG1,16 mm2,2 kg/km3,7 kg/km Send inquiry
3349 .. 24*24/7 AWG1,16 mm2,2 kg/km3,7 kg/km Send inquiry
3348 .. 22*22/7 AWG1,31 mm3,5 kg/km5,2 kg/km Send inquiry
3349 .. 22*22/7 AWG1,31 mm3,5 kg/km5,2 kg/km Send inquiry
3348 .. 20*20/7 AWG1,51 mm5,4 kg/km7,5 kg/km Send inquiry
3349 .. 20*20/7 AWG1,51 mm5,4 kg/km7,5 kg/km Send inquiry
3348 .. 18*18/19 AWG1,78 mm9,2 kg/km12 kg/km Send inquiry
3349 .. 18*18/19 AWG1,78 mm9,2 kg/km12 kg/km Send inquiry
3348 .. 16*16/19 AWG1,94 mm11,8 kg/km14 kg/km Send inquiry
3349 .. 16*16/19 AWG1,94 mm11,8 kg/km14 kg/km Send inquiry
3348 .. 14*14/19 AWG2,3 mm18,7 kg/km22 kg/km Send inquiry
3349 .. 14*14/19 AWG2,3 mm18,7 kg/km22 kg/km Send inquiry
3348 .. 12*12/19 AWG2,76 mm29,7 kg/km33 kg/km Send inquiry
3349 .. 12*12/19 AWG2,76 mm29,7 kg/km33 kg/km Send inquiry
item no.
AWG
max. outer-ø
Copper figure
Cable weight ≈
3348 .. 28*
28/7 AWG
0,93 mm
0,9 kg/km
2 kg/km
3349 .. 28*
28/7 AWG
0,93 mm
0,9 kg/km
2 kg/km
3348 .. 26*
26/7 AWG
1,03 mm
1,3 kg/km
2,7 kg/km
3349 .. 26*
26/7 AWG
1,03 mm
1,3 kg/km
2,7 kg/km
3348 .. 24*
24/7 AWG
1,16 mm
2,2 kg/km
3,7 kg/km
3349 .. 24*
24/7 AWG
1,16 mm
2,2 kg/km
3,7 kg/km
3348 .. 22*
22/7 AWG
1,31 mm
3,5 kg/km
5,2 kg/km
3349 .. 22*
22/7 AWG
1,31 mm
3,5 kg/km
5,2 kg/km
3348 .. 20*
20/7 AWG
1,51 mm
5,4 kg/km
7,5 kg/km
3349 .. 20*
20/7 AWG
1,51 mm
5,4 kg/km
7,5 kg/km
3348 .. 18*
18/19 AWG
1,78 mm
9,2 kg/km
12 kg/km
3349 .. 18*
18/19 AWG
1,78 mm
9,2 kg/km
12 kg/km
3348 .. 16*
16/19 AWG
1,94 mm
11,8 kg/km
14 kg/km
3349 .. 16*
16/19 AWG
1,94 mm
11,8 kg/km
14 kg/km
3348 .. 14*
14/19 AWG
2,3 mm
18,7 kg/km
22 kg/km
3349 .. 14*
14/19 AWG
2,3 mm
18,7 kg/km
22 kg/km
3348 .. 12*
12/19 AWG
2,76 mm
29,7 kg/km
33 kg/km
3349 .. 12*
12/19 AWG
2,76 mm
29,7 kg/km
33 kg/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00