TA 867 CF

FEP connection cable with extended temperature range and overall copper screen

Marking for TA 867 CF 38670415:
SAB BRÖCKSKES · D-VIERSEN · TA 867 CF AWG 16/4c cULus AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3867-0415 CE

Marking for TA 867 CF 38670415: SAB BRÖCKSKES · D-VIERSEN · TA 867 CF AWG 16/4c cULus AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3867-0415 CE

Application

This FEP connection cable with a copper braiding is suitable for use up to 180°C. Due to its very high resistance to acids, halogens, bases, chlorinated solvents and organic and inorganic compounds, this cable is used in high-frequency and broadband technology.

Outstanding features

  • excellent resistance against chemicals and solvents
  • excellent temperature resistance and flexibility at low temperatures
  • excellent electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics
  • UL/cUL recognized

Construction

Conductor

tinned copper strands acc. to IEC 60228, VDE 0295, class 5

Insulation

FEP, 6YI1 acc. to VDE 0207-6

Colour code

coloured acc. to HD 308 (VDE 0293-308), from 6 cores black cores with consecutive numbers

acc. to EN 50334 + VDE 0293-334, from 3 cores a green-yellow earth wire

Stranding

in layers

Wrapping

foil

Screen

tinned copper braiding

Sheath material

FEP, 6YM1 acc. to VDE 0207-6

Sheath colour

black (RAL 9005)

Conductor

tinned copper strands acc. to IEC 60228, VDE 0295, class 5

Insulation

FEP, 6YI1 acc. to VDE 0207-6

Colour code

coloured acc. to HD 308 (VDE 0293-308), from 6 cores black cores with consecutive numbers

acc. to EN 50334 + VDE 0293-334, from 3 cores a green-yellow earth wire

Stranding

in layers

Wrapping

foil

Screen

tinned copper braiding

Sheath material

FEP, 6YM1 acc. to VDE 0207-6

Sheath colour

black (RAL 9005)

Technical data

Nominal voltage

Uo/U 300/500 V

Voltage UL/cUL

600 V

Testing voltage

core/core 2000 V

core/screen 2000 V

Min. bending radius

7,5 x d

Radiation resistance

1 x 10⁷ cJ/kg

Temperature range

DIN VDE fixed laying: -90/+180 °C

DIN VDE flexible application: -55/+180 °C

UL/cUL: up to +150 °C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT1, FT2

Oil resistance

very good acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases,

chlorinated solvents as well as organic and

inorganic compounds

Absence of harmful substances

gemäß RoHS-Richtlinie der Europäischen Union

Nominal voltage

Uo/U 300/500 V

Voltage UL/cUL

600 V

Testing voltage

core/core 2000 V

core/screen 2000 V

Min. bending radius

7,5 x d

Radiation resistance

1 x 10⁷ cJ/kg

Temperature range

DIN VDE fixed laying: -90/+180 °C

DIN VDE flexible application: -55/+180 °C

UL/cUL: up to +150 °C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT1, FT2

Oil resistance

very good acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases,

chlorinated solvents as well as organic and

inorganic compounds

Absence of harmful substances

gemäß RoHS-Richtlinie der Europäischen Union

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00