SAB Kabel

Th LRS

Fibre-glass insulated extension cables for thermocouples with special fibre-glass braiding and steel wire armouring

Application

Th LRS is a fibre-glass insulated extension cable for thermocouples with special fibre-glass braiding and steel wire armouring. This thermocouple wire withstands a temperature of up to max. 400°C.

Additional information

Construction

Insulation

special fibre-glass

Stranding

cores together

Braiding

special fibre-glass

Armouring

galvanized steel wire armouring with tracer

Shape

round

For thermocouples

■ 1 x type T     ■ 1 x type J      ■ 1 x type K

■ 1 x type E     ■ 1 x type R/S     ■ 1 x type N

■ 1 x type L     ■ 1 x type U      ■ 1 x type B

Insulation

special fibre-glass

Stranding

cores together

Braiding

special fibre-glass

Armouring

galvanized steel wire armouring with tracer

Shape

round

For thermocouples

■ 1 x type T     ■ 1 x type J      ■ 1 x type K

■ 1 x type E     ■ 1 x type R/S     ■ 1 x type N

■ 1 x type L     ■ 1 x type U      ■ 1 x type B

Technical data

Min. bending radius

12 x d

Temperature range

max. +400°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

no flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24

resp. IEC 60332-3-25 + VDE 0482-332-3-25

Cat. C resp. D, see chapter N „Technical Data“.

Flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2.

Absence of harmful substances

acc. to RoHS directive of the European Union

Min. bending radius

12 x d

Temperature range

max. +400°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

no flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24

resp. IEC 60332-3-25 + VDE 0482-332-3-25

Cat. C resp. D, see chapter N „Technical Data“.

Flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2.

Dimensions

item no. type no. of cores x cross section conductor construction approx. outer-ø cable weight ca.
047210…*Th 20 LRS2 x 0,22 mm²0,22 mm² = 7 x 0,20 mm øNiCr-Ni3,1 mm1,9 kg/100m Send inquiry
047211…*Th 50 LRS2 x 0,50 mm²0,50 mm² = 16 x 0,20 mm øNiCr-Ni3,7 mm3,9 kg/100m Send inquiry
047212…*Th 100 LRS2 x 1,00 mm²1,00 mm² = 32 x 0,20 mm øNiCr-Ni4,5 mm5,2 kg/100m Send inquiry
047213…*Th 20 -4 LRS4 x 0,22 mm²0,22 mm² = 7 x 0,20 mm øNiCr-Ni3,5 mm2,9 kg/100m Send inquiry
047214…*Th 50 -4 LRS4 x 0,50 mm²0,50 mm² = 16 x 0,20 mm øNiCr-Ni4,2 mm5,1 kg/100m Send inquiry
047215…*Th 100-4 LRS4 x 1,00 mm²1,00 mm² = 32 x 0,20 mm øNiCr-Ni5,4 mm7,5 kg/100m Send inquiry
item no.
type
no. of cores x cross section
conductor construction
approx. outer-ø
cable weight ca.
047210…*
Th 20 LRS
2 x 0,22 mm²
0,22 mm² = 7 x 0,20 mm ø
NiCr-Ni
3,1 mm
1,9 kg/100m
047211…*
Th 50 LRS
2 x 0,50 mm²
0,50 mm² = 16 x 0,20 mm ø
NiCr-Ni
3,7 mm
3,9 kg/100m
047212…*
Th 100 LRS
2 x 1,00 mm²
1,00 mm² = 32 x 0,20 mm ø
NiCr-Ni
4,5 mm
5,2 kg/100m
047213…*
Th 20 -4 LRS
4 x 0,22 mm²
0,22 mm² = 7 x 0,20 mm ø
NiCr-Ni
3,5 mm
2,9 kg/100m
047214…*
Th 50 -4 LRS
4 x 0,50 mm²
0,50 mm² = 16 x 0,20 mm ø
NiCr-Ni
4,2 mm
5,1 kg/100m
047215…*
Th 100-4 LRS
4 x 1,00 mm²
1,00 mm² = 32 x 0,20 mm ø
NiCr-Ni
5,4 mm
7,5 kg/100m

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00