S PB 634 HT Hybrid

combined Profibus-DP cable with supply cores for the high temperature, continuously flexible

Marking for S PB 634 HT Hybrid 36341307:
SAB BRÖCKSKES · D-VIERSEN · S PB 634 HT 2 x 0,34 mm² + 3 x 0,75 mm² CE

Marking for S PB 634 HT Hybrid 36341307: SAB BRÖCKSKES · D-VIERSEN · S PB 634 HT 2 x 0,34 mm² + 3 x 0,75 mm² CE

Application

Combined Profibus-DP hybrid cable with supply cores for the high temperature, continuously flexible.

Outstanding features

  • extreme temperature resistance
  • high notch resistance
  • very good flexibility

Construction

Conductor

tinned copper strands, extra fine wires

Core insulation

PFA

Colour code

0,34 mm² red, green

supply cores acc. to HD 308

Stranding

0,34 mm² twisted to pairs

Wrapping

PTFE foil

Inner sheath

special Besilen®

Screen 0,34 mm²

tinned copper braiding

Inner sheath

FEP

Stranding

element 0,34 mm² together with supply cores

Wrapping

PTFE foil

Outer sheath

special Besilen®

Sheath colour

blue lilac (similar RAL 4005)

Conductor

tinned copper strands, extra fine wires

Core insulation

PFA

Colour code

0,34 mm² red, green

supply cores acc. to HD 308

Stranding

0,34 mm² twisted to pairs

Wrapping

PTFE foil

Inner sheath

special Besilen®

Screen 0,34 mm²

tinned copper braiding

Inner sheath

FEP

Stranding

element 0,34 mm² together with supply cores

Wrapping

PTFE foil

Outer sheath

special Besilen®

Sheath colour

blue lilac (similar RAL 4005)

Technical data

Nominal voltage

Uo/U 300/500 V (supply cores)

Peak operating voltage

max. 350 V (0,34 mm²)

Testing voltage

0,34 mm²:

core/core 1500 V

core/screen 1200 V

 

supply cores:

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

continuously flexible: 15 x d

Temperature range

fixed laying: - 40°C / + 180°C

flexible application: - 25°C / + 180°C

short time use: + 250°C

Characteristic impedance PB element (3-20 MHz)

150Ω ± 10%

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Flexibility

very good

Absence of harmful substances

acc. to RoHS directive of the European Union

Nominal voltage

Uo/U 300/500 V (supply cores)

Peak operating voltage

max. 350 V (0,34 mm²)

Testing voltage

0,34 mm²:

core/core 1500 V

core/screen 1200 V

 

supply cores:

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

continuously flexible: 15 x d

Temperature range

fixed laying: - 40°C / + 180°C

flexible application: - 25°C / + 180°C

short time use: + 250°C

Characteristic impedance PB element (3-20 MHz)

150Ω ± 10%

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Flexibility

very good

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Dimension Approx. outer-ø Copper figure Cable weight ≈
L363413072 x 0,34 mm² + 3 x 0,75 mm²12,0 mm54,9 kg/km190 kg/km Send inquiry
L363414072 x 0,34 mm² + 4 x 0,75 mm²12,0 mm62,1 kg/km191 kg/km Send inquiry
L363415102 x 0,34 mm² + 5 x 1,00 mm²12,2 mm81,3 kg/km229 kg/km Send inquiry
L363413152 x 0,34 mm² + 3 x 1,50 mm²12,6 mm76,5 kg/km215 kg/km Send inquiry
L363414152 x 0,34 mm² + 4 x 1,50 mm²12,6 mm90,9 kg/km235 kg/km Send inquiry
item no.
Dimension
Approx. outer-ø
Copper figure
Cable weight ≈
L36341307
2 x 0,34 mm² + 3 x 0,75 mm²
12,0 mm
54,9 kg/km
190 kg/km
L36341407
2 x 0,34 mm² + 4 x 0,75 mm²
12,0 mm
62,1 kg/km
191 kg/km
L36341510
2 x 0,34 mm² + 5 x 1,00 mm²
12,2 mm
81,3 kg/km
229 kg/km
L36341315
2 x 0,34 mm² + 3 x 1,50 mm²
12,6 mm
76,5 kg/km
215 kg/km
L36341415
2 x 0,34 mm² + 4 x 1,50 mm²
12,6 mm
90,9 kg/km
235 kg/km

Other dimensions and colours are possible on request.