HV 1000 - SCP

Highly flexible silicone-insulated high-voltage single conductor with PUR outer sheath and overall copper screen

Marking example: SAB BRÖCKSKES · D-VIERSEN · HV 1000–SCP 10mm² ATTENTION HIGH VOLTAGE MAX 600 V AC / 1000 V DC

Marking example: SAB BRÖCKSKES · D-VIERSEN · HV 1000–SCP 10mm² ATTENTION HIGH VOLTAGE MAX 600 V AC / 1000 V DC

Application

High-voltage cable with PUR outer sheath  for extremely high mechanical strength and silicone insulation, specifically designed for electric and hybrid vehicles. 
Used in the powertrain, batteries, inverters and power electronics.

Outstanding features

  • extremely high mechanical strength
  • oil resistant
  • good EMC characteristics
  • very flexible
  • weather resistant
  • halogen-free
  • Operating range from -50°C to +125°C
  • PFAS-free
     

Additional information

Certifications - Construction, materials and tests with reference to:

 

  • LV 216-2
  • DIN EN 13602
  • DIN EN 50525
  • DIN EN 50363
  • DIN EN 50620
  • DIN EN 60811

In individual cases, the specific application must be agreed with SAB Bröckskes.

Construction

Conductor

bare copper strands, extra fine wires, CU ETP-1 acc. to EN 13602, max. 0,21 mm single-wire diameter

Insulation

silicone

Screen

tinned copper braiding

optical coverage ≥ 85%

aluminum-laminated foil, with the metal side on the inside

Sheath material

PUR

Sheath colour

orange (RAL 2003)

Conductor

bare copper strands, extra fine wires, CU ETP-1 acc. to EN 13602, max. 0,21 mm single-wire diameter

Insulation

silicone

Screen

tinned copper braiding

optical coverage ≥ 85%

aluminum-laminated foil, with the metal side on the inside

Sheath material

PUR

Sheath colour

orange (RAL 2003)

Technical data

Standard basis dimensions

LV 216-2

Operating voltage

600 V AC / 1000 V DC

Testing voltage

spark test 8000 V

core/screen 5000 V

Min. bending radius

fixed laying: 3 x d

flexible application: 5 x d

Temperature range

-50/+90 °C

short time use: +125 °C (2000 h)

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Oil resistance

very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2

UV- and weather resistance

acc. to HD 605

UV- and weather resistance

nach DIN EN 50396

Mechanical characteristics outer sheath

- high tear strength

- high tensile strength

- high abrasion resistance

- high notch resistance

- high shear strength

Absence of harmful substances

acc. to RoHS directive of the European Union

Standard basis dimensions

LV 216-2

Operating voltage

600 V AC / 1000 V DC

Testing voltage

spark test 8000 V

core/screen 5000 V

Min. bending radius

fixed laying: 3 x d

flexible application: 5 x d

Temperature range

-50/+90 °C

short time use: +125 °C (2000 h)

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

UV- and weather resistance

acc. to HD 605

UV- and weather resistance

nach DIN EN 50396

Mechanical characteristics outer sheath

- high tear strength

- high tensile strength

- high abrasion resistance

- high notch resistance

- high shear strength

Absence of harmful substances

acc. to RoHS directive of the European Union

HV 1000 - SCP (Abmessung nach LV 216-2)

item no. Nominal cross
section
Approx. core-ø Outer-ø Copper figure Cable weight ≈ Ohmic resistance
at 20°C max.
L3916232710,00 mm²6,0 -0,6 mm8,8 -0,6 mm134,8 kg/km164 kg/km1,91 Ω/km Send inquiry
L3916233716,00 mm²7,2 -0,6 mm10,2 -0,6 mm201,0 kg/km235 kg/km1,21 Ω/km Send inquiry
L3916234725,00 mm²8,8 -0,6 mm12,2 -0,6 mm321,6 kg/km354 kg/km0,78 Ω/km Send inquiry
L3916235735,00 mm²10,5 -0,7 mm14,4 -0,6 mm433,5 kg/km488 kg/km0,554 Ω/km Send inquiry
L3916236750,00 mm²12,2 -0,7 mm15,8 -0,6 mm581,2 kg/km623 kg/km0,386 Ω/km Send inquiry
L3916237770,00 mm²14,4 -1,4 mm18,2 -0,8 mm794,6 kg/km866 kg/km0,227 Ω/km Send inquiry
L3916238795,00 mm²17,2 -1,4 mm20,9 -0,8 mm1097,0 kg/km1167 kg/km0,206 Ω/km Send inquiry
L39162397120,00 mm²19,7 -1,8 mm23,5 -1,0 mm1354,0 kg/km1440 kg/km0,161 Ω/km Send inquiry
item no.
Nominal cross
section
Approx. core-ø
Outer-ø
Copper figure
Cable weight ≈
Ohmic resistance
at 20°C max.
L39162327
10,00 mm²
6,0 -0,6 mm
8,8 -0,6 mm
134,8 kg/km
164 kg/km
1,91 Ω/km
L39162337
16,00 mm²
7,2 -0,6 mm
10,2 -0,6 mm
201,0 kg/km
235 kg/km
1,21 Ω/km
L39162347
25,00 mm²
8,8 -0,6 mm
12,2 -0,6 mm
321,6 kg/km
354 kg/km
0,78 Ω/km
L39162357
35,00 mm²
10,5 -0,7 mm
14,4 -0,6 mm
433,5 kg/km
488 kg/km
0,554 Ω/km
L39162367
50,00 mm²
12,2 -0,7 mm
15,8 -0,6 mm
581,2 kg/km
623 kg/km
0,386 Ω/km
L39162377
70,00 mm²
14,4 -1,4 mm
18,2 -0,8 mm
794,6 kg/km
866 kg/km
0,227 Ω/km
L39162387
95,00 mm²
17,2 -1,4 mm
20,9 -0,8 mm
1097,0 kg/km
1167 kg/km
0,206 Ω/km
L39162397
120,00 mm²
19,7 -1,8 mm
23,5 -1,0 mm
1354,0 kg/km
1440 kg/km
0,161 Ω/km

Other dimensions and colours are possible on request.

Downloads

    Highly flexible cables according to your special requirements

    Family business for construction and production since 1947

    Please send us your inquiry
    +49 (0)2162 898-0
    Monday to Thursday, 7.30–16.30
    Friday, 07.30–13.30

    Hello!

    Your preferred language does not match the language of this site. You can switch to the appropriate translation.