M-103 C

8 x 2 x AWG 22/7

Construction

Conductor

tinned copper, stranded

Colour code

8x black, green, blue, purple, grey, brown, red, orange, yellow

Stranding

pairs twisted in specially adjusted layering

Screen

aluminium foil, metallized non-woven tape and tinned copper braiding, wrapped with foil

Conductor

tinned copper, stranded

Colour code

8x black, green, blue, purple, grey, brown, red, orange, yellow

Stranding

pairs twisted in specially adjusted layering

Screen

aluminium foil, metallized non-woven tape and tinned copper braiding, wrapped with foil

Technical Data

Operating voltage

36 V

Testing voltage

core/core 500 V

core/screen 500 V

Temperature range

fixed laying: -50/+125 °C

flexible use: -40/+125 °C

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Fire performance

no flame propagation acc. to IEC 60332-3

flame retardant and self extinguishing acc. to IEC 60332-1-2

Smoke density

acc. to IEC 61034

Chemical resistance

general good against oils, fuels and saltwater

Vibration resistance

good

UV- and ozone resistance

good

Marking resistance

acc. to EN 50305 10.1

Halogen free

acc. to IEC 60754-1

Corrosivity

acc. to IEC 60754-2

no development of corrosive conflagration gases

Toxicity

acc. to EN 50305

Characteristic impedance

max. 36 mΩ/m at 0,1 up to 10 MHz

(measured on production-no. K238608)

Screen attenuation

min. 67,5 dB, nom. 74 dB at 1 up to 50 MHz

(measured on production-no. K238608)

Absence of harmful substances

acc. to RoHS directive of the European Union

Operating voltage

36 V

Testing voltage

core/core 500 V

core/screen 500 V

Temperature range

fixed laying: -50/+125 °C

flexible use: -40/+125 °C

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Fire performance

no flame propagation acc. to IEC 60332-3

flame retardant and self extinguishing acc. to IEC 60332-1-2

Smoke density

acc. to IEC 61034

Chemical resistance

general good against oils, fuels and saltwater

Vibration resistance

good

UV- and ozone resistance

good

Marking resistance

acc. to EN 50305 10.1

Halogen free

acc. to IEC 60754-1

Corrosivity

acc. to IEC 60754-2

no development of corrosive conflagration gases

Toxicity

acc. to EN 50305

Characteristic impedance

max. 36 mΩ/m at 0,1 up to 10 MHz

(measured on production-no. K238608)

Screen attenuation

min. 67,5 dB, nom. 74 dB at 1 up to 50 MHz

(measured on production-no. K238608)

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Outer-ø Copper figure Cable weight ≈ Ohmic resistance
at 20°C max.
L5503901213,9 mm +/- 1 mm123,7 kg/km220,0 kg/kmmax. 54,8 Ω/km Send inquiry
item no.
Outer-ø
Copper figure
Cable weight ≈
Ohmic resistance
at 20°C max.
L55039012
13,9 mm +/- 1 mm
123,7 kg/km
220,0 kg/km
max. 54,8 Ω/km

Other dimensions and colours are possible on request.