P-625 C

2 x AWG 26 CB + 1 x AWG 26

Construction

Conductor

tinned copper, fine stranded

Insulation

SABIX®

Colour code

CAN-Bus: white, brown

ground: grey

Stranding

cores stranded in optimised position, fleece wound overlapping

Screen

braid of tinned copper wires,

opt. coverage ≥90%, fleece wound overlapping

Outer jacket

PUR, gentian blue, similar to RAL 5010

Print

P-625 C 5565-0314.009

Conductor

tinned copper, fine stranded

Insulation

SABIX®

Colour code

CAN-Bus: white, brown

ground: grey

Stranding

cores stranded in optimised position, fleece wound overlapping

Screen

braid of tinned copper wires,

opt. coverage ≥90%, fleece wound overlapping

Outer jacket

PUR, gentian blue, similar to RAL 5010

Print

P-625 C 5565-0314.009

Technical Data

Peak operating voltage

max. 350 V

Testing voltage

core/core 1500 V

core/screen 1200 V

Temperature range

fixed laying: -50/+90 °C

flexible application: -40/+90 °C

 

limited operating:

+100 °C / 15000 h

+120 °C / 4000 h

+125 °C / 2500 h

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Data transmission

cores white/brown, characteristic impedance 120 Ω (95-140 Ω)

Oil resistance

very good - TMPU acc. to EN 50363-10-2 

Chemical characteristics

generally good resistance to fuels and solvents

Absence of harmful substances

acc. to RoHS directive of the European Union

REACH

The designated article does not contain any substances of very high concern (SVHC) from the candidate list according to Article 59 of Regulation (EC) No 1907/2006 concerning the registration, evaluation, authorisation and restriction of chemicals.

Peak operating voltage

max. 350 V

Testing voltage

core/core 1500 V

core/screen 1200 V

Temperature range

fixed laying: -50/+90 °C

flexible application: -40/+90 °C

 

limited operating:

+100 °C / 15000 h

+120 °C / 4000 h

+125 °C / 2500 h

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Data transmission

cores white/brown, characteristic impedance 120 Ω (95-140 Ω)

Oil resistance
Chemical characteristics

generally good resistance to fuels and solvents

Absence of harmful substances

acc. to RoHS directive of the European Union

REACH

The designated article does not contain any substances of very high concern (SVHC) from the candidate list according to Article 59 of Regulation (EC) No 1907/2006 concerning the registration, evaluation, authorisation and restriction of chemicals.

Dimensions

item no. Outer-ø Copper figure Cable weight ≈ Ohmic resistance
at 20°C max.
L55650314ca. 4,7 mm17,8 kg/km30,0 kg/km142,9 Ω/km Send inquiry
item no.
Outer-ø
Copper figure
Cable weight ≈
Ohmic resistance
at 20°C max.
L55650314
ca. 4,7 mm
17,8 kg/km
30,0 kg/km
142,9 Ω/km

Other dimensions and colours are possible on request.

Downloads

    Highly flexible cables according to your special requirements

    Family business for construction and production since 1947

    Please send us your inquiry
    +49 (0)2162 898-0
    Monday to Thursday, 7.30–16.30
    Friday, 07.30–13.30

    Hello!

    Your preferred language does not match the language of this site. You can switch to the appropriate translation.