Application
CAT 7A halogen-free Ethernet cable with ABS Type Approval and UL recognition is especially for use in shipbuilding industry.
Outstanding features
- ABS Type Approval
- TR IEC 60092-370
- halogen-free
- asbestos-free
- lame retardant and self-extinguishing
- no flame propagation
- UL recognized
- PFAS-free
Additional information
Also possible as harnessed cable with M12 or RJ 45 plug.
For use in propulsion systems, additional unit certification by ABS is required.
Please contact us if the cable is intended for such an application.
Construction
| Dimension | 4 x 2 x 24 AWG 4 x 2 x 26 AWG |
|---|---|
| Conductor | bare copper strands, fine wires |
| Insulation | special polymer |
| Colour code | white-blue/blue, white-orange/orange, white-green/green, white-brown/brown |
| Stranding | cores twisted to pairs, pairs screened with foil, pairs together |
| Wrapping | alu foil |
| Screen | tinned copper braiding |
| Sheath material | special SABIX® |
| Sheath colour | black |
4 x 2 x 24 AWG
4 x 2 x 26 AWG
bare copper strands, fine wires
special polymer
white-blue/blue, white-orange/orange, white-green/green, white-brown/brown
cores twisted to pairs, pairs screened with foil, pairs together
alu foil
tinned copper braiding
special SABIX®
black
Technical data
| Peak operating voltage | max. 90 V |
|---|---|
| Voltage UL | 300 V |
| Testing voltage | core/core 2000 V core/screen 2000 V |
| Min. bending radius | fixed laying: 5 x d flexible application: 10 x d |
| Temperature range VDE | fixed laying: - 40°C / + 70 °C flexible application: - 30°C / + 70 °C UL: up to + 75°C |
| Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
| Flame propagation | no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A, UL Horizontal Flame Test FT2, UL AWM Style 21080 |
| Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
| Corrosiveness of conflagration gases | in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases |
| Smoke density | acc. to IEC 61034 + VDE 0482-1034 |
| Characteristic impedance | 100Ω ± 10Ω, fulfils the electrical and transmission requirements with high frequency with reference to EN 50288-9-2 / CAT 7A |
| Flexibility | good |
| UL Style | 21080 |
| Application | suitable for EtherCAT and EtherNET/IP applications |
| Absence of harmful substances | acc. to RoHS directive of the European Union |
max. 90 V
300 V
core/core 2000 V
core/screen 2000 V
fixed laying: 5 x d
flexible application: 10 x d
fixed laying: - 40°C / + 70 °C
flexible application: - 30°C / + 70 °C
UL: up to + 75°C
acc. to IEC 60754-1 + VDE 0482-754-1
no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A,
UL Horizontal Flame Test FT2, UL AWM Style 21080
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
acc. to IEC 61034 + VDE 0482-1034
100Ω ± 10Ω, fulfils the electrical and transmission requirements
with high frequency with reference to EN 50288-9-2 / CAT 7A
good
21080
suitable for EtherCAT and EtherNET/IP applications
acc. to RoHS directive of the European Union
Dimensions
| item no. | Dimension |
Outer-ø ± 10% | Copper figure | Cable weight ≈ | |
|---|---|---|---|---|---|
| L17474621 | 4 x 2 x 26/7 AWG | 8,9 mm | 38,5 kg/km | 85 kg/km | Send inquiry |
| L17474421 | 4 x 2 x 24/7 AWG | 10,5 mm | 65 kg/km | 116 kg/km | Send inquiry |
± 10%