Application
Grounding wire with braiding on the conductor to improve dimensional stability and contact. The design is particularly suitable for use on rail vehicles. The copper grounding wire is used as current or ground connection.
Outstanding features
- extremely flexible
- halogen-free
- heat resistant
- flexible at low temperatures
- flame retardant and self-extinguishing
- weather resistant
- PFAS-free
Additional information
Colour code for single conductors:
1 = green-yellow 5 = green
2 = blue 6 = white
3 = black 7 = orange
4 = brown 8 = red
Construction
| Conductor | bare copper strands, extra fine wires |
|---|---|
| Screen | bare copper braiding |
| Insulation | Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1 |
| Colour | translucent |
bare copper strands, extra fine wires
bare copper braiding
Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1
translucent
Technical data
| Nominal voltage | 4,0 - 6,0 mm²: Uo/U 1,5/1,5 kV 10,0 - 150,0 mm²: Uo/U 1,8/3,0 kV |
|---|---|
| Testing voltage | 4,0 - 6,0 mm²: 4000 V 10,0 - 150,0 mm²: 6500 V |
| Current-carrying capacity | acc. to VDE 0298-4 |
| Min. bending radius | 5 x d |
| Temperature range | fixed laying: -40/+180°C flexible application: -25/+180°C short-time use: +250°C |
| Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
| Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
| Corrosiveness of conflagration gases | IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases |
| Weather resistance | very good |
| Absence of harmful substances | acc. to RoHS directive of the European Union |
4,0 - 6,0 mm²: Uo/U 1,5/1,5 kV
10,0 - 150,0 mm²: Uo/U 1,8/3,0 kV
4,0 - 6,0 mm²: 4000 V
10,0 - 150,0 mm²: 6500 V
acc. to VDE 0298-4
5 x d
fixed laying: -40/+180°C
flexible application: -25/+180°C
short-time use: +250°C
acc. to IEC 60754-1 + VDE 0482-754-1
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
very good
acc. to RoHS directive of the European Union
Dimensions
| item no. |
Nominal cross section |
Largest single wire-ø | Copper figure | Cable weight ≈ |
Outer-ø ± 10% | |
|---|---|---|---|---|---|---|
| L01080400 | 4 mm² | 0,07 mm | 53,7 kg/km | 66 kg/km | 5,7 mm | Send inquiry |
| L01080600 | 6 mm² | 0,07 mm | 73,3 kg/km | 86 kg/km | 6,1 mm | Send inquiry |
| L01081000 | 10 mm² | 0,07 mm | 116,3 kg/km | 164 kg/km | 9,4 mm | Send inquiry |
| L01081600 | 16 mm² | 0,07 mm | 174,2 kg/km | 213 kg/km | 9,7 mm | Send inquiry |
| L01082500 | 25 mm² | 0,1 mm | 285,9 kg/km | 351 kg/km | 12,6 mm | Send inquiry |
| L01083500 | 35 mm² | 0,1 mm | 388,3 kg/km | 467 kg/km | 14,4 mm | Send inquiry |
| L01085000 | 50 mm² | 0,1 mm | 542,1 kg/km | 623 kg/km | 16,3 mm | Send inquiry |
| L01087000 | 70 mm² | 0,1 mm | 771,8 kg/km | 852 kg/km | 18,5 mm | Send inquiry |
| L01089500 | 95 mm² | 0,1 mm | 1023,5 kg/km | 1093 kg/km | 19,6 mm | Send inquiry |
| L01081200 | 120 mm² | 0,1 mm | 1268,0 kg/km | 1335 kg/km | 22,8 mm | Send inquiry |
| L01081500 | 150 mm² | 0,1 mm | 1593,3 kg/km | 1667 kg/km | 24,5 mm | Send inquiry |
section
wire-ø
± 10%
Other dimensions and colours are possible on request.