2 x (2 x 0,25mm²) D + 2 x (2 x 0,34mm²) D + 1,0 + (2 x 0,29mm²) D + 2 x (2 x 1,0mm²) D Operating voltage: max. 350 V, Voltage UL: 30 V, Testing voltage: core/core 1000 V core/screen 700 V, Temperature range: flexible application: -40/+70 °C UL: up to +80 °C, Min. bending radius: recommended: 12 x d a, Absence of harmful substances: acc. to RoHS directive of the European Union Conductor: bare resp. tinned copper strands acc. to IEC 60228, Sheath material: PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2, Sheath colour: redlilac (RAL 4001) 0616-9028
4 x 1,0mm² + 5 x 2 x 0,25mm² + 1 x 1,0mm² Nominal voltage: max. 350 V, Testing voltage: core/core 1700 V core/screen 1000 V, Temperature range: flexible application: -40/+70 °C, Min. bending radius: recommended: 10 x d, Absence of harmful substances: acc. to RoHS directive of the European Union Conductor: bare copper strands acc. to IEC 60228, Insulation: special Polymer / TPE, Colour code: with reference to DIN 47100 + black, blue, red, brown, green-yellow, Sheath material: PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2, Sheath colour: redlilac (RAL 4001) 0367-9048
23 x 1,0 mm² + (2 x 1,0 mm²) D or 16 x 1,0 mm² + (2 x 1,0 mm²) D Peak operating voltage: max. 600 V, Testing voltage: core/core 2000 V core/screen 1200 V, Temperature range: flexible application: -40/+90 °C, Min. bending radius: recommended: 10 x d, Absence of harmful substances: acc. to RoHS directive of the European Union Conductor: tinned copper strands acc. to IEC 60228, Insulation: TPE, Colour code: white cores with consecutive numbers acc. to EN 50334 + VDE 0293-334 and a green-yellow earth wire, Inner sheath: TPE, Sheath material: PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2, Sheath colour: black (RAL 9005) 0764-9065, 0764-9079
2 x 2 x 22 AWG Profinet CAT 5 cable « Type R » for robotic applications. The recommended torsion angle of this robotic cable is ±180°/m. The stranding of the cores 2 x 2 x 22 AWG can be provided as star quad or twisted pairs.robotic applications type RWe assemble our cables with connectors of all well-known manufacturers. Peak operating voltage: max. 350 V, Testing voltage: core/core 1500 V core/screen 1200 V, Temperature range: flexible application: -30/+70 °C, Torsion angle: recommended: ±180°/m, Absence of harmful substances: acc. to RoHS directive of the European Union Conductor: tinned copper strands acc. to IEC 60228, Colour code: white, blue, orange, yellow, Stranding: twisted paires, resp. twisted to star quad, Sheath material: PUR, Sheath colour: green (RAL 6018) 0668-9001, 0668-9039
Item no.: L0668-9001, Peak operating voltage: max. 350 V, Testing voltage: cond./cond. 1500 V cond./screen 1200 V, Temperature range: fixed laying: -40° up to +90°C flexible application: -30°C up to +90°C, Min. bending radius: static: 5 x outer diameter flexing: 10 x outer diameter, Absence of harmful substances: acc. to RoHS directive of the European Union Dimension: 2 x 2 x AWG 22, Conductor: tinned copper strands, Core isolation: PE, Colour code: white, blue, orange, yellow, Wrapping: alu foil, Screen: tinned copper braiding, Wrapping: non-woven tape, Outer sheath: PUR, Sheath colour: black
5 x (2 x 0,75 mm²)D + 22 x 0,75 mm² Nominal voltage: Uo/U 300/500 V, Testing voltage: core/core 2000 V (AC) core/screen 2000 V (AC), Temperature range: flexible application: -40/+80 °C, Min. bending radius: recommended: 10 x d, Absence of harmful substances: acc. to RoHS directive of the European Union Conductor: bare copper strands acc. to IEC 60228, Insulation: TPE, Colour code: white cores with consecutive numbers acc. to EN 50334 + VDE 0293-334 and a green-yellow earth wire, Sheath material: PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 with mat surface, Control cable for welding guns: black (RAL 9005) 0796-9081
Multi conductor welding cable for robotic applications Operating voltage: ≤ 16,0 mm² = 500 V (DC) ≥ 25,0 mm² = 750 V (DC), Testing voltage: ≤ 16,0 mm² = 1500 V (AC) ≥ 25,0 mm² = 2000 V (AC), Temperature range: flexible application: -40/+90 °C, Min. bending radius: recommended: 7,5 x d, Halogen-free: acc. to IEC 60754-1 + VDE 0482-754-1, Absence of harmful substances: acc. to RoHS directive of the European Union Conductor: bare copper strands acc. to IEC 60228, Insulation: PUR, Colour code: black cores with consecutive numbers acc. to EN 50334 + VDE 0293-334, green-yellow earth wire from 3 cores, Sheath material: PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2, Sheath colour: 10-2 + VDE 0207-363-10-2 Sheath colour: b 0774-9111, 0774-9084, 0774-9085, 0774-9088
with Silicone impregnated fibre-glass braiding For the wiring of motors /generators / transformers. Suitable for the potting with impregnating materials for example with epoxy resin. Residues can be easily removed from the silicone impregnated surfaces.halogen-free flexible at low temperatures heat resistant good mechanical characteristics fibre-glass braiding up to +400°C Nominal voltage: Uo/U 450/750 V Uo/U 3,8/6,6 V Uo/U 8,0/13,8 V, Testing voltage: 450/750 V = 2500 V 3,8/6,6 kV = 15000 V 8,0/13,8 kV = 30000 V, Mind. bending radius: 7,5 x d, Radiation resistance: 2 x 10^7 cJ/kg, Temperature range: fixed laying: -40°C / +180°C flexible application: -25°C / +180°C short-time use: +250°C, Halogen-free: acc. to IEC 60754-1 + VDE 0482-754-1, Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, Corrosiveness of conflagration gases: in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases, Absence of harmful substances: acc. to RoHS directive of the European Union Conductor: tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5, Wrapping: non-woven tape, Insulation: special silicone, Colour code: 450/750 V: white 3,8/6,6 kV: grey 8,0/13,8 kV: black, Braiding: fibre-glass, Impregnation: special silicon
3 x 1,0mm² + 4 x 0,5mm² + 3 x 3 x 0,5mm² + (2 x 0,5mm²) D Peak operating voltage: max. 500 V, Testing voltage: core/core 1500 V core/screen 1200 V, Temperature range: flexible application: -40/+90 °C, Min. bending radius: recommended: 10 x d, Absence of harmful substances: acc. to RoHS directive of the European Union Conductor: bare copper strands acc. to IEC 60228, Insulation: TPE, Colour code: white cores with consecutive numbers acc. to EN 50334 + VDE 0293-334 and a green-yellow earth wire, Sheath material: PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2, Sheath colour: sky blue (RAL 5015) 0399-0157
16 x 1,0 mm² + (2 x 1,0 mm²)D Item no.: L0764-9079, Peak operating voltage: max. 350 V, Testing voltage: cond./cond. 1500 V cond./screen 1000 V, Temperature range: fixed laying: -50°C up to +90°C flexible application: -40°C up to +90°C, Min. bending radius: flexing: 10 x outer diameter, Absence of harmful substances: acc. to RoHS directive of the European Union Dimension: 16 x 1,0 mm² + (2 x 1,0 mm²)D, Conductor: tinned copper strands, Core isolation: TPE, Colour code: black cores with consecutive numbers + green/yellow earth wire, Wrapping: non-woven tape, Screen: tinned copper braiding, Inner sheath: PUR, black, Outer sheath: PUR, black