S IBS 618

PUR Interbus-S cable for cable tracks with UL recognition

Marking example: SAB BRÖCKSKES · D-VIERSEN · 06183251 3 x 2 x 0,25 mm² S IBS 618 24 AWG/3pr UL AWM Style 20235 80°C voltage not specified CE

Marking example: SAB BRÖCKSKES · D-VIERSEN · 06183251 3 x 2 x 0,25 mm² S IBS 618 24 AWG/3pr UL AWM Style 20235 80°C voltage not specified CE

Application

This PUR Interbus-S cable for cable tracks with UL approval is halogen-free according to DIN VDE 0472 part 815 and IEC 60754-1. It is used in transport and storage technology and production engineering.

Outstanding features

  • UL recognition
  • suitable for cable tracks
  • halogen-free
  • flame retardant and self-extinguishing
  • very good oil resistance
  • very good weather resistance
  • PFAS-free

Additional information

Interbus-S remote bus cables and Interbus-S installation remote bus cables are used for the sensor/actuator level of industrial communication.

Not sure which bus cables are right for your application?

Compare more SAB bus cables and use their technical specifications to find the right cable for your application.

Compare and select bus cables

Construction

Dimension

Remote Bus cable: 3 x 2 x 0,25 mm²

Installation Remote Bus cable: 3 x 2 x 0,25 mm² + 3 x 1,00mm²

Conductor

0,25 mm²: bare copper strands with reference to VDE 0812

1,00 mm²: bare copper strands acc. to IEC 60228, VDE 0295, class 6

Insulation

0,25 mm²: PE, 2YI1 acc. to EN 50290-2-23 + VDE 0819-103

1,00 mm²: TPE

Colour code

0,25 mm²: acc. to DIN 47100

1,00 mm²: red, blue and a green-yellow earth wire

Stranding

0,25 mm²: twisted to pairs

1,00 mm²: pairs and cores together

Wrapping

non-woven tape

Screen

tinned copper braiding

Sheath material

PUR, TMPU acc. to EN 50363-10-2 with rough surface

Sheath colour

redlilac (RAL 4001)

Dimension

Remote Bus cable: 3 x 2 x 0,25 mm²

Installation Remote Bus cable: 3 x 2 x 0,25 mm² + 3 x 1,00mm²

Conductor

0,25 mm²: bare copper strands with reference to VDE 0812

1,00 mm²: bare copper strands acc. to IEC 60228, VDE 0295, class 6

Insulation

0,25 mm²: PE, 2YI1 acc. to EN 50290-2-23 + VDE 0819-103

1,00 mm²: TPE

Colour code

0,25 mm²: acc. to DIN 47100

1,00 mm²: red, blue and a green-yellow earth wire

Stranding

0,25 mm²: twisted to pairs

1,00 mm²: pairs and cores together

Wrapping

non-woven tape

Screen

tinned copper braiding

Sheath material

PUR, TMPU acc. to EN 50363-10-2 with rough surface

Sheath colour

redlilac (RAL 4001)

Technical data

Peak operating voltage

max. 350 V

Voltage UL

300 V

Testing voltage

core/core: 2000V

core/screen: 2000V

Min. bending radius

7,5 x d

Radiation resistance

5 x 10^7 cJ/kg

Temperature range

UL: up to +80 °C

fixed laying: -40/+70 °C

flexible application: -40/+70 °C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Oil resistance

very good - acc. to EN 50363-10-2 + VDE 0207-363-10-2

Characteristic impedance at 0.064 MHz

120 Ω ± 20%

Characteristic impedance at > 1 MHz

100 Ω ± 15%

Flexibility

very good

Application in cable tracks

recommended

Weather resistance

very good

Bending characteristics

number of bendings acc. to VDE 0472-603 test methode H: min. 1.000.000 single bendings

Direct Burial

suitable

UL Style

20235

Absence of harmful substances

acc. to RoHS directive of the European Union

Peak operating voltage

max. 350 V

Voltage UL

300 V

Testing voltage

core/core: 2000V

core/screen: 2000V

Min. bending radius

7,5 x d

Radiation resistance

5 x 10^7 cJ/kg

Temperature range

UL: up to +80 °C

fixed laying: -40/+70 °C

flexible application: -40/+70 °C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Characteristic impedance at 0.064 MHz

120 Ω ± 20%

Characteristic impedance at > 1 MHz

100 Ω ± 15%

Flexibility

very good

Application in cable tracks

recommended

Weather resistance

very good

Bending characteristics

number of bendings acc. to VDE 0472-603 test methode H: min. 1.000.000 single bendings

Direct Burial

suitable

UL Style

20235

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Type Dimension Outer-ø ± 10% Copper figure Cable weight ≈
L06183251Remote bus cable3 x 2 x 0,25 mm²8,5 mm35,9 kg/km82 kg/km Send inquiry
L06186251Installation remote bus cable3 x 2 x 0,25 mm² + 3 x 1,00 mm²9,2 mm71 kg/km116 kg/km Send inquiry
item no.
Type
Dimension
Outer-ø ± 10%
Copper figure
Cable weight ≈
L06183251
Remote bus cable
3 x 2 x 0,25 mm²
8,5 mm
35,9 kg/km
82 kg/km
L06186251
Installation remote bus cable
3 x 2 x 0,25 mm² + 3 x 1,00 mm²
9,2 mm
71 kg/km
116 kg/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–13.30

Hello!

Your preferred language does not match the language of this site. You can switch to the appropriate translation.