Application
This PUR Interbus-S cable for cable tracks with UL approval is halogen-free according to DIN VDE 0472 part 815 and IEC 60754-1. It is used in transport and storage technology and production engineering.
Outstanding features
- UL recognition
- suitable for cable tracks
- halogen-free
- flame retardant and self-extinguishing
- very good oil resistance
- very good weather resistance
- PFAS-free
Additional information
Interbus-S remote bus cables and Interbus-S installation remote bus cables are used for the sensor/actuator level of industrial communication.
Construction
| Dimension | Remote Bus cable: 3 x 2 x 0,25 mm² Installation Remote Bus cable: 3 x 2 x 0,25 mm² + 3 x 1,00mm² |
|---|---|
| Conductor | 0,25 mm²: bare copper strands with reference to VDE 0812 1,00 mm²: bare copper strands acc. to IEC 60228, VDE 0295, class 6 |
| Insulation | 0,25 mm²: PE, 2YI1 acc. to EN 50290-2-23 + VDE 0819-103 1,00 mm²: TPE |
| Colour code | 0,25 mm²: acc. to DIN 47100 1,00 mm²: red, blue and a green-yellow earth wire |
| Stranding | 0,25 mm²: twisted to pairs 1,00 mm²: pairs and cores together |
| Wrapping | non-woven tape |
| Screen | tinned copper braiding |
| Sheath material | PUR, TMPU acc. to EN 50363-10-2 with rough surface |
| Sheath colour | redlilac (RAL 4001) |
Remote Bus cable: 3 x 2 x 0,25 mm²
Installation Remote Bus cable: 3 x 2 x 0,25 mm² + 3 x 1,00mm²
0,25 mm²: bare copper strands with reference to VDE 0812
1,00 mm²: bare copper strands acc. to IEC 60228, VDE 0295, class 6
0,25 mm²: PE, 2YI1 acc. to EN 50290-2-23 + VDE 0819-103
1,00 mm²: TPE
0,25 mm²: acc. to DIN 47100
1,00 mm²: red, blue and a green-yellow earth wire
0,25 mm²: twisted to pairs
1,00 mm²: pairs and cores together
non-woven tape
tinned copper braiding
PUR, TMPU acc. to EN 50363-10-2 with rough surface
redlilac (RAL 4001)
Technical data
| Peak operating voltage | max. 350 V |
|---|---|
| Voltage UL | 300 V |
| Testing voltage | core/core: 2000V core/screen: 2000V |
| Min. bending radius | 7,5 x d |
| Radiation resistance | 5 x 10^7 cJ/kg |
| Temperature range | UL: up to +80 °C fixed laying: -40/+70 °C flexible application: -40/+70 °C |
| Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
| Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
| Oil resistance | very good - acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
| Characteristic impedance at 0.064 MHz | 120 Ω ± 20% |
| Characteristic impedance at > 1 MHz | 100 Ω ± 15% |
| Flexibility | very good |
| Application in cable tracks | recommended |
| Weather resistance | very good |
| Bending characteristics | number of bendings acc. to VDE 0472-603 test methode H: min. 1.000.000 single bendings |
| Direct Burial | suitable |
| UL Style | 20235 |
| Absence of harmful substances | acc. to RoHS directive of the European Union |
max. 350 V
300 V
core/core: 2000V
core/screen: 2000V
7,5 x d
5 x 10^7 cJ/kg
UL: up to +80 °C
fixed laying: -40/+70 °C
flexible application: -40/+70 °C
acc. to IEC 60754-1 + VDE 0482-754-1
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
very good - acc. to EN 50363-10-2 + VDE 0207-363-10-2
120 Ω ± 20%
100 Ω ± 15%
very good
recommended
very good
number of bendings acc. to VDE 0472-603 test methode H: min. 1.000.000 single bendings
suitable
20235
acc. to RoHS directive of the European Union
Dimensions
| item no. | Type | Dimension | Outer-ø ± 10% | Copper figure | Cable weight ≈ | |
|---|---|---|---|---|---|---|
| L06183251 | Remote bus cable | 3 x 2 x 0,25 mm² | 8,5 mm | 35,9 kg/km | 82 kg/km | Send inquiry |
| L06186251 | Installation remote bus cable | 3 x 2 x 0,25 mm² + 3 x 1,00 mm² | 9,2 mm | 71 kg/km | 116 kg/km | Send inquiry |
Other dimensions and colours are possible on request.