Li6Ybl · Li6Yvz (375 V)

FEP insulated stranded hook-up wire with extended temperature range, 375 V

Application

Li6Ybl · Li6Yvz is an ETFE, FEP, and PFA insulated stranded hook-up wire with extended temperature range and high resistance against chemicals 375 V. It is recommended for use in high-frequency and broad-band techniques, coaxial and microwave techniques, high information velocity with exact information transmission at the same time, chemical industry, furnace construction, brick works, and heating appliances.

Outstanding features

  • excellent resistance against chemicals and solvents
  • excellent temperature resistance and flexibility at low temperatures
  • excellent electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics

Additional information

ETFE, FEP, PFA colour code,

figures 5 and 6 item-no.:

 

01 = black05 = yellow09 = orange
02 = blue06 = green11 = red
03 = brown07 = violet15 = nature
04 = grey08 = white 

Construction

Conductor

bare or tinned-plated copper strands

acc. to ASTM B 286

Insulation

FEP, 6YI1 acc. to VDE 0207-6

Conductor

bare or tinned-plated copper strands

acc. to ASTM B 286

Insulation

FEP, 6YI1 acc. to VDE 0207-6

Technical data

Peak operating voltage

max. 375 V

Voltage UL

600 V

Testing voltage

2000 V

Installation

for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated wire

Radiation resistance

1 x 10⁷ cJ/kg

Temperature range

fixed laying: -90/+180°C

flexible application: -55/+180°C

limited time of use: 200 °C

UL: up to +150°C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT2

Oil resistance

very good acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds – FEP has a slightly better resistance than ETFE

Absence of harmful substances

acc. to RoHS directive of the European Union

Peak operating voltage

max. 375 V

Voltage UL

600 V

Testing voltage

2000 V

Installation

for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated wire

Radiation resistance

1 x 10⁷ cJ/kg

Temperature range

fixed laying: -90/+180°C

flexible application: -55/+180°C

limited time of use: 200 °C

UL: up to +150°C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT2

Oil resistance

very good acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds – FEP has a slightly better resistance than ETFE

Absence of harmful substances

acc. to RoHS directive of the European Union

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00