Selection Table ETFE-, FEP-, PFA Cables
The selection table for ETFE-, FEP-, and PFA cables is the first decision support to choose the correct cable for your special application. On the corresponding product page you will find the technical data and characteristics . In case that you don´t find the appropriate cable solution, we are always prepared to assist you. We design and produce special cables on request of the customer that is tailor-made to your requirements and application field.
You would like to have a direct contact to our experts? Please call us or send an e-mail!
Cable type | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Basic construction | ETFE cable |
|
|
|
|
|
|
|
|
|
|
|
| |
FEP cable |
|
|
| |||||||||||
PFA cable |
|
|
|
|
|
|
|
|
|
|
| |||
Single conductor |
|
|
|
|
|
| ||||||||
Datacable |
|
|
|
|
|
|
|
|
|
| ||||
Connection cable |
|
|
|
|
|
|
|
|
|
| ||||
Copper strands acc. to ASTM B 286 |
|
|
| |||||||||||
Copper strands acc. to |
|
|
|
|
|
|
|
|
|
| ||||
Colour code with reference to DIN 47100 |
|
|
|
|
|
|
|
|
|
| ||||
Colour code acc. to HD 308 |
|
|
|
|
|
|
|
|
|
|
| |||
Colour code acc. to EN 50334 + VDE 0293-334 |
|
|
|
|
|
|
|
|
|
|
|
| ||
Screened |
|
|
|
|
|
|
|
|
| |||||
Twisted pairs |
|
|
|
|
|
|
|
|
|
|
|
| ||
Temperature range | +260 °C |
|
| ⬤ |
|
|
| ⬤ |
|
|
|
|
|
|
+250 °C |
|
| ⬤ |
|
|
| ⬤ |
|
|
|
|
|
| |
+200 °C | ⬤ | ⬤ |
| ⬤ | ⬤ | ⬤ | ⬤ | ⬤ |
|
|
| |||
+180 °C | ⬤ | ⬤ |
| ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | |||
+150 °C | ⬤ | |||||||||||||
+135 °C | ⬤ | |||||||||||||
– 90 °C | ||||||||||||||
Voltage | Peak operating voltage max. 375 V |
|
|
|
|
|
|
| ||||||
Peak operating voltage max. 900 V |
|
|
|
|
|
|
|
|
| |||||
Nominal voltage Uo/U 300/500 V |
|
|
|
|
|
|
|
|
|
| ||||
Voltage UL 600 V |
| |||||||||||||
Voltage cUL 600 V |
|
|
|
|
|
|
| |||||||
Testing voltage 2000 V |
|
|
|
| ||||||||||
Testing voltage 2500 V |
|
|
|
|
|
|
|
|
| |||||
Standards | UL recognized |
| ||||||||||||
cUL recognized |
|
|
|
|
|
|
| |||||||
Approvals: DNV |
|
|
|
|
|
|
|
|
|
|
|
| ||
Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 | ||||||||||||||
Fire performance: UL FT1 |
|
|
|
|
|
|
| |||||||
Fire performance: UL FT2 |
| |||||||||||||
Fire performance: no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 cat. A |
|
|
|
|
|
|
|
|
|
|
|
| ||
Characteristics | Chemical resistance | |||||||||||||
Oil resistance acc. to UL standard 758 |
| |||||||||||||
Oil and fuel resistance |
|
|
|
|
|
|
|
|
|
|
|
| ||