LiPFAvn (375 V)

PFA insulated stranded hook-up wire with extended temperature range, 375 V

Application

LiPFAvn is an PFA insulated stranded hook-up wire with extended temperature range and high resistance against chemicals 375 V. It is recommended for use in high-frequency and broad-band techniques, coaxial and microwave techniques, high information velocity with exact information transmission at the same time, chemical industry, furnace construction, brick works, and heating applicances.

Outstanding features

  • excellent resistance against chemicals and solvents
  • excellent temperature resistance and flexibility at low temperatures
  • excellent electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics
  • UL recognized

Additional information

ETFE, FEP, PFA colour code, figures 5 and 6 item-no.:

 

01 = black05 = yellow09 = orange
02 = blue06 = green11 = red
03 = brown07 = violet15 = nature
04 = grey08 = white 

 

Construction

Conductor

nickel-plated copper strands acc. to ASTM B 286

Insulation

PFA, 51YI1 acc. to VDE 0207-6

Conductor

nickel-plated copper strands acc. to ASTM B 286

Insulation

PFA, 51YI1 acc. to VDE 0207-6

Technical data

Peak operating voltage

max. 375 V

Voltage UL

600 V

Testing voltage

2000 V

Installation

for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated strands

Radiation resistance

1 x 10⁶ cJ/kg

Temperature range

fixed laying: -90/+250 °C

flexible application: -55/+250 °C

limited time of use: +260 °C

UL: up to +250 °C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT2

Oil resistance

very good acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases,

chlorinated solvents as well as organic and

inorganic compounds

Absence of harmful substances

gemäß RoHS-Richtlinie der Europäischen Union

Peak operating voltage

max. 375 V

Voltage UL

600 V

Testing voltage

2000 V

Installation

for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated strands

Radiation resistance

1 x 10⁶ cJ/kg

Temperature range

fixed laying: -90/+250 °C

flexible application: -55/+250 °C

limited time of use: +260 °C

UL: up to +250 °C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT2

Oil resistance

very good acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases,

chlorinated solvents as well as organic and

inorganic compounds

Absence of harmful substances

gemäß RoHS-Richtlinie der Europäischen Union

Dimensions

item no. Dimension nominal single
wire-ø
Approx. outer-ø Copper figure Cable weight ≈
L3344 .. 28*AWG 28/70,127 mm0,71 mm0,9 kg/km1,4 kg/km Send inquiry
L3344 .. 26*AWG 26/70,160 mm0,80 mm1,4 kg/km2,0 kg/km Send inquiry
L3344 .. 24*AWG 24/70,203 mm0,93 mm2,2 kg/km2,9 kg/km Send inquiry
L3344 .. 22*AWG 22/70,254 mm1,08 mm3,4 kg/km4,2 kg/km Send inquiry
L3344 .. 20*AWG 20/70,320 mm1,28 mm5,4 kg/km6,3 kg/km Send inquiry
item no.
Dimension
nominal single
wire-ø
Approx. outer-ø
Copper figure
Cable weight ≈
L3344 .. 28*
AWG 28/7
0,127 mm
0,71 mm
0,9 kg/km
1,4 kg/km
L3344 .. 26*
AWG 26/7
0,160 mm
0,80 mm
1,4 kg/km
2,0 kg/km
L3344 .. 24*
AWG 24/7
0,203 mm
0,93 mm
2,2 kg/km
2,9 kg/km
L3344 .. 22*
AWG 22/7
0,254 mm
1,08 mm
3,4 kg/km
4,2 kg/km
L3344 .. 20*
AWG 20/7
0,320 mm
1,28 mm
5,4 kg/km
6,3 kg/km

*Colour code figures 5 and 6. ─ ETFE insulated strands on request. ─ Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00