Application

BiAF/YW is a low-voltage connection cable for halogen lamps. Due to its silicone core insulation, it is suitable for temperatures up to 180°C at conductors. Additionally, it is space saving due to its flat construction. Moreover, it is applied as connection cable for low-voltage lamps and connection between transformer and halogen lamp.

Outstanding features

  • due to silicone core insulation suitable for temperatures up to 180°C at conductors
  • heat resistant PVC outer sheath for ambient temperatures up to 105°C for short-time use
  • due to flat construction space-saving
  • simplified connecting possibilities
  • no wiring with single conductors
  • PFAS-free

Not sure which silicone cables are right for your application?

Compare more SAB silicone cables and use their technical specifications to find the right cable for your application.

Compare and select silicone cables

Construction

Conductor

bare copper strands acc. to IEC 60228, VDE 0295, class 5

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1

Colour code

blue, red

Stranding

2 cores parallel

Sheath material

PVC, TM4 acc. to EN 50363-4-1 + VDE 0207-363-4-1

Sheath colour

black (similar RAL 9005)

Shape

flat

Conductor

bare copper strands acc. to IEC 60228, VDE 0295, class 5

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1

Colour code

blue, red

Stranding

2 cores parallel

Sheath material

PVC, TM4 acc. to EN 50363-4-1 + VDE 0207-363-4-1

Sheath colour

black (similar RAL 9005)

Shape

flat

Technical data

Nominal voltage

24 V

Testing voltage

core/core 600 V

Min. bending radius

7,5 x d

Radiation resistance

8 x 10^7 cJ/kg

Temperature range

fixed laying: -40/+90 °C

flexible application: +5/+90°C

short-time use: +105°C

at the conductor: +180°C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Chem. resistance

see "Technical Data" - Chemical resistance

Absence of harmful substances

acc. to RoHS directive of the European Union

Nominal voltage

24 V

Testing voltage

core/core 600 V

Min. bending radius

7,5 x d

Radiation resistance

8 x 10^7 cJ/kg

Temperature range

fixed laying: -40/+90 °C

flexible application: +5/+90°C

short-time use: +105°C

at the conductor: +180°C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Chem. resistance

see "Technical Data" - Chemical resistance

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. No. of cores x
cross section
Largest single
wire-ø
Dimension Copper figure Cable weight ≈
L013521512 x 1,50 mm²0,26 mm5,8 mm x 3,5 mm28,8 kg/km44 kg/km Send inquiry
L013522512 x 2,50 mm²0,26 mm6,8 mm x 4,0 mm48 kg/km66 kg/km Send inquiry
L013524012 x 4,00 mm²0,31 mm7,8 mm x 4,4 mm76,8 kg/km96 kg/km Send inquiry
item no.
No. of cores x
cross section
Largest single
wire-ø
Dimension
Copper figure
Cable weight ≈
L01352151
2 x 1,50 mm²
0,26 mm
5,8 mm x 3,5 mm
28,8 kg/km
44 kg/km
L01352251
2 x 2,50 mm²
0,26 mm
6,8 mm x 4,0 mm
48 kg/km
66 kg/km
L01352401
2 x 4,00 mm²
0,31 mm
7,8 mm x 4,4 mm
76,8 kg/km
96 kg/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–13.30

Hello!

Your preferred language does not match the language of this site. You can switch to the appropriate translation.