SAB Kabel

A 11 Lr

2 Silicone (Besilen®) insulated cores with fibre-glass braiding and steel wire armouring, conductor construction: 1,5 mm² strand

Application

This thermocable type K (NiCr-Ni) is designed as a compensation or thermocable. The conductor cross section can also be offered in 1.0 mm², 0.75 mm², 0.55 mm² and 0.22 mm² on request. Further thermocouples can be freely selected from the following types: Type K, type J, Tyn L, type N, type S, type R.

Outstanding features

  • flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Additional information

We also manufacture compensating and extension cables colour coded to VDE 43714 – 06/79 and the basic values laid down in VDE 43710 which was withdrawn in April 1994.
 

Type:A 11 LrA 11-4 Lr 
Conductor cross section: 1,5 mm²1,5 mm²
Outer diameter: approx. 6,3 mmapprox. 7,3 mm
Weight/100m:approx. 5,9 kgapprox. 9,6 kg


C = compensating cables · X = extension cablesDIN 43710 / 43714 (not valid for type B*)
* Not standardized compensating cable for thermocouples type B with application temperatures up to 100 °C resp. 200 °C.

Construction

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1

Stranding

2 resp. 4 cores together

Braiding

fibre-glass with tracer

Armouring

galvanized steel wire armouring with tracer

Shape

round

Conductor construction

strand

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1

Stranding

2 resp. 4 cores together

Braiding

fibre-glass with tracer

Armouring

galvanized steel wire armouring with tracer

Shape

round

Conductor construction

strand

Technical data

Min. bending radius

10 x d

Temperature range of insulation

fixed laying: -40/+180°C

flexible application: -25/+180°C

short-time use: +250°C

Insulation resistance

> 1 M Ω x km

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosiveness of conflagration gases

in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Absence of harmful substances

acc. to RoHS directive of the European Union

Min. bending radius

10 x d

Temperature range of insulation

fixed laying: -40/+180°C

flexible application: -25/+180°C

short-time use: +250°C

Insulation resistance

> 1 M Ω x km

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosiveness of conflagration gases

in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00