SAB Kabel

A 4 Ln

Silicone (Besilen®) insulated cable with steel wire armouring, cores parallel

Application

The type k thermocouple cable A 4 Ln has a tinned steel wire armouring with tracer. Moreover, it has an oval shape and a conductor construction of strands. This cable is also available in cross-sections of 1,0 mm², 0,75 mm², 0,50 mm², and 0,22 mm².

Additional information

Type:A 4 Ln
Conductor cross section: 1,5 mm² 
Outer diameter:approx. 4,5 x 7,0 mm
Weight/100m: approx. 7,5 kg

DIN 43710 / 43714 (not valid for type B*)
* Not standardized compensating cable for thermocouples type B with application temperatures up to 100 °C resp. 200 °C.
C = compensating cables · X = extension cables

 

Construction

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1

Stranding

2 cores parallel

Sheath material

Besilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1

Armouring

tinned steel wire armouring with tracer

Shape

oval

Conductor construction

strand

For thermocouples

■ 1 x type T     ■ 1 x type J      ■ 1 x type K

■ 1 x type E     ■ 1 x type R/S     ■ 1 x type N

■ 1 x type L     ■ 1 x type U      ■ 1 x type B

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1

Stranding

2 cores parallel

Sheath material

Besilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1

Armouring

tinned steel wire armouring with tracer

Shape

oval

Conductor construction

strand

For thermocouples

■ 1 x type T     ■ 1 x type J      ■ 1 x type K

■ 1 x type E     ■ 1 x type R/S     ■ 1 x type N

■ 1 x type L     ■ 1 x type U      ■ 1 x type B

Technical data

Min. bending radius

12 x d

Radiation resistance

2 x 10^7 cJ/kg

Temperature range of insulation

fixed laying: -40/+180°C

flexible application: -25/+180°C

short-time use: +250°C

Insulation resistance

> 1 M Ω x km

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosiveness of conflagration gases

in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Absence of harmful substances

acc. to RoHS directive of the European Union

Min. bending radius

12 x d

Radiation resistance

2 x 10^7 cJ/kg

Temperature range of insulation

fixed laying: -40/+180°C

flexible application: -25/+180°C

short-time use: +250°C

Insulation resistance

> 1 M Ω x km

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosiveness of conflagration gases

in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00