Skip navigation

Special Cables • Temperature Measurement • Cable Harnessing

SABIX® A 147 FRNC

Halogen-free wiring cable 600 V acc. to UL

Marking for SABIX A 147 FRNC 61470150: SAB BRÖCKSKES · D-VIERSEN · SABIX A 147 FRNC 300/500V 0,5 mm² 20 AWG UL AWM Style 10528 75°C 60OV CE

Marking for SABIX A 147 FRNC 61470150: SAB BRÖCKSKES · D-VIERSEN · SABIX A 147 FRNC 300/500V 0,5 mm² 20 AWG UL AWM Style 10528 75°C 60OV CE

Application

SABIX® A 147 FRNC is a flame retardant, halogen-free wiring cable with a voltage of 600 V. This electrical cable with UL is recommended for use in production of control cabinets, appliances and devices for communication technologies, household appliances, construction of generators and transformers, machine construction, and railway technologies: furthermore, the FRNC type is particulary suitable for internal wiring of rail vehicles.

Outstanding features

  • halogen-free
  • no flame propagation
  • flame retardant and self-extinguishing
  • UL recognized
  • EAC approval

Additional information

On request as multi-core cable possible

* Colour code for single conductors:

01 = black

02 = blue 
03 = brown
04 = grey 
05 = yellow

06 = green
07 = violet 
08 = white 
16 = gentian blue 
27 = green-yellow

Cable construction

Conductor

tinned copper strands acc. to IEC 60228, EN 60228, VDE 0295 class 5

Insulation

SABIX®

Sheath colour

coloured

Technical data

Nominal voltage

0,50 - 1,0 mm²: 300/500 V

Voltage

UL: 20 - 18 AWG: 600 V

Testing voltage

2000 V

Min. bending radius

7,5 x d

 

For one single bend:

5 x d

Temperature range

DIN VDE fixed laying: -40/+90 °C

DIN VDE flexible application: -30/+90 °C

UL: up to +75°C

Halogen-free

acc. to DIN VDE 0472 part 815 + IEC 60754-1

Fire performance

no flame propagation acc. to IEC 60332 + EN 60332 CAT. C resp. D. Flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2

Corrosiveness of conflagration gases

In compliance with IEC 60754-2, EN 50267-2-2 + VDE 0482 part 267-2-2 - no development of corrosive conflagration gases

Smoke density

acc. to IEC 61034 + EN 61034

Flexibility

good

Weather resistance

good

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. nominal cross section AWG/ MCM largest single wire-ø outer-ø ± 5% copper figure cable weight ca.
6147 .. 50* 0,5 mm² 20 (15/32) 0,21 mm 2,1 mm 4,8 kg/km 9 kg/km
6147 .. 75* 0,75 mm² 19 (23/32) 0,21 mm 2,4 mm 7,2 kg/km 12 kg/km
6147 .. 80* 1 mm² 18 (30/32) 0,21 mm 2,5 mm 9,6 kg/km 15 kg/km